Sportsman GEN3500i Instruction Manual

Sportsman GEN3500i Instruction Manual

3,000 max watts inverter generator

Advertisement

Quick Links

GEN3500
i
3,000 MAX WATTS INVERTER GENERATOR
INSTRUCTION MANUAL
R E A D A L L I N S T R U C T I O N S A N D W A R N I N G S B E F O R E U S I N G T H I S
P R O D U C T .
This manual provides important information on proper operation & maintenance. Every effort has been
made to ensure the accuracy of this manual. These instructions are not meant to cover every possible
condition and situation that may occur. We reserve the right to change this product at any time without
prior notice.
I F T H E R E I S A N Y Q U E S T I O N A B O U T A C O N D I T I O N B E I N G S A F E O R U N S A F E ,
D O N O T O P E R A T E T H I S P R O D U C T !
D O N O T R E T U R N T H I S G E N E R A T O R T O T H E R E T A I L E R !
If you experience a problem, have questions or need parts for this product, call Customer Service at
1-866-460-9436, Monday-Friday, 8 AM - 4 PM Central Time. A copy of the sales receipt is required.
FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE.
KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR
FUTURE REFERENCE.
CALIFORNIA PROPOSITION 65
WARNING:
This product, or the exhaust from this generator, may contain chemicals, including lead,
known to the State of California to cause cancer and birth defects or other reproductive harm. Wash
hands after handling.
 
 
1

Advertisement

Table of Contents
loading

Summary of Contents for Sportsman GEN3500i

  • Page 1 GEN3500 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL R E A D A L L I N S T R U C T I O N S A N D W A R N I N G S B E F O R E U S I N G T H I S P R O D U C T .
  • Page 2: Year Limited Warranty

    2 YEAR LIMITED EMISSION-RELATED WARRANTY THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .The emission- related limited warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase. Buffalo Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center.
  • Page 3: Important Safety Instructions

    Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine Modifications (EM).
  • Page 4 According to the State of California, the exhaust from this generator Chemicals: contains chemicals known to cause cancer, birth defects, or other reproductive harm. This generator may emit highly flammable and explosive Flammable Gasoline: gasoline vapors, which can cause severe burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.
  • Page 5 NOTE: DO NOT USE GASOLINE CONTAINING MORE THAN 10% ETHANOL (e10) Consult a physician(s) before using this generator if using a pacemaker. Usage: Electromagnetic fields in close proximity to a heart pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. Prolonged exposure to high noise levels can be hazardous to hearing.
  • Page 6 This generator produces heat when in operation. High Temperatures: Temperatures near the exhaust can exceed 150 Degrees Fahrenheit (65 Degrees Celsius). • Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. • Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and before storing indoors.
  • Page 7 Misuse of this generator can damage it or shorten its life. Usage: • Use this generator only for its intended purpose. • Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.
  • Page 8 Avoid the use of extension cords if possible. If you choose to use them, be Usage: sure they are sized adequately to handle the flow of electricity. An undersized cord can overheat, short out and cause a fire.    ...
  • Page 9 FEATURES: •1.7 Gallon Fuel Tank •3,000 Watts Max AC output •5,000 RPM •149cc, 4 stroke •Low oil shutdown •Recoil Start •Run Time : 5 Hours at 50% load •Noise Level : 63db at 0% load @23 Ft DC connector wires for connecting 12 Volt automotive-type batteries, Spark Plug...
  • Page 10: Engine Switch

    This  is a Gasoline Powered Invertor Generator  that  offers  clean  power  for  electronics. 1) ENGINE SWITCH The engine switch controls the ignition system. To Start generator, turn ignition switch ON. Then the engine can be started by sliding Choke lever to CHOKE then pull Recoil.
  • Page 11: Dc Circuit Protector

    5) DC CIRCUIT PROTECTOR The DC circuit protector turns off automatically when the load exceeds the generator rated output. Reduce the load to within specified generator rated output if the DC circuit protector turns off. 6) FUEL COCK The fuel cock is used to supply fuel from the tank to the carburetor. Turn ON when getting ready to start the generator.
  • Page 12: Check Engine Oil

    CHECK ENGINE OIL Remove side panel, then remove oil filler cap and check the engine oil level. Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary. WARNING: The generator has been shipped without engine oil. Fill with oil or it will not start.   l...
  • Page 13: Stopping The Engine

    USING ELECTRIC POWER AC APPLICATION (a) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator. Insert the plug(s) of the electrical appliance(s) into the receptacle. l Be sure the electric apparatus is turned off before plugging in. l...
  • Page 14: Periodic Maintenance

    PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is most important for the best performance and safe operation. Pre-operati o n Ini t i a l Every Every Every Item Remarks check 1 months 3 months 6 months 12 months (dai l y ) or 20 Hr or 50Hr or100Hr...
  • Page 15: Engine Oil Replacement

    Cool i n g Check fan damage. l system Starti n g Check recoi l starter operati o n. l system Idl e speed Check and adj u st engi n e i d l e speed l Fi t ti n gs / Check al l fi t ti n gs and fasteners correct i f l...
  • Page 16: Cleaning And Adjusting Spark Plug

    l Be sure no foreign material enters the crankcase.   Do not tilt the generator when adding engine oil. l This could result in overfilling and damage to the   engine Oil Drain Clean the oil filter every other 100 hr. l...
  • Page 17: Fuel Tank Filter

    FUEL TANK FILTER 1. Remove the fuel tank cap and filter. 2. Clean the filter with solvent. If damaged, replace. 3. Wipe the filter and insert it. Be sure the tank cap is tightened securely. MUFFLER SCREEN l The engine and muffler will be very hot after the engine has been run.
  • Page 18: Drain The Fuel

    Engine oil system Insufficient l Oil level is low….Add engine oil. Electrical systems Poor spark l Spark plug dirty with carbon or wet….Remove carbon or wipe spark plug dry. l Faulty ignition system….Consult dealer. Compression insufficient l Worn out piston and cylinder….Consult dealer. Generator won’t produce power Safety device (AC) to “OFF”...
  • Page 19 5. Clean exterior of the generator and apply a rust inhibitor. 6. Store the generator in a dry, well-ventilated place, with the cover place over it. 7. The generator must remain in a vertical position. MODEL GEN3500i Type Inverter Generator 60Hz...
  • Page 20 Lubricating oil SAE 10W30 Lubricating oil Capacity 30 oz Starting System Recoil Starter Ignition system C.D.I Spark Plug: Type A7RTC Net dimension L×W×H 614 x 341 x 506mm Overall dimension L×W×H 640 x 360 x 525mm Net Weight 33.5 Kg Dry Weight 36.5Kg l...
  • Page 21: Storage Instructions

    STORAGE INSTRUCTIONS Rotate gas valve to “OFF” position.         Remove three screws from engine air box           Rotate the engine air box Locate carburetor.   Remove drain screw from side of carburetor   Fuel will begin to drain out of bowl  ...
  • Page 22: Wiring Diagram

      bowl and fuel line. To remove remaining fuel from fuel line, open   cap at top of generator. WIRING DIAGRAM    ...
  • Page 23        ...
  • Page 24    ...
  • Page 25    ...
  • Page 26    ...
  • Page 27    ...
  • Page 28    ...
  • Page 29    ...
  • Page 30 2 0 1 6 0 5    ...