Protection Function

Charger Fuse

• Before replacing the fuse, get rid of the excessive electric current. Changing the
fuse without solution cause fuse cut off again.
• Always replace a fuse with the one of the correct rating. Using a wrong fuse
may result in damage to electrical components or cause fire.
Fuse Holder
4105M-0501-040US
Ciruit Breaker
This product is fitted with a circuit breaker, which cuts off the electric current to prevent the
damages to machine in case of overcurrent. If circuit breaker trips, press breaker reset
button to reset.
Breaker Reset
4104M-0505-010US
Maintenance
1.
Turn charge switch [OFF] and disconnect
power cable from power outlet.
2.
Remove fuse folder and replace the fuse.
3.
Install fuse holder.
NOTE
• Fuse to Use: See "Page 24"
Resetting
1.
Turn main switch [OFF].
2.
Solve the cause of overcurrent.
3.
Press circuit breaker reset button.
NOTE
• Cut or pinched wire may cause circuit
breaker to trip. If circuit breaker keeps
tripping after resetting, please contact your
CANYCOM representative.