3. SPECIFICATIONS

3.1. Robot specifiactions
• Motor protection: IP 68
• Minimum pool depth: 0.80m (2.6ft)
• Maximum pool depth: 5m (16.4ft)
The pool water conditions must be within the following parameters:
PH
Temperature
Salt
Chlorine
3.2. Charger specifications
Digital switch-mode charger:
• Input: 100-250AC volts
• Output: 26 VDC
3.3. Battery specifications
• Application: Robotic pool cleaner
• Battery type: Lithium ion
• Battery Configuration: 6S4P
• Nominal Voltage: 22.2V
• Maximum Charge Voltage: 25.2V
• Discharge Cut-off Voltage: 18V
• Typical Capacity: 10400mAh
• Standard Discharge Current: 1.7A
• Maximum Charging Current: 4.5A
• Operating Temperature: 0-45°C (charging)
• Storage Temperature: 0-30°C
• Safety Device: Each cell is equipped with a safety vent system. Each pack is equipped with a
protection circuit against over-voltage, over-discharge and over-current.
• Safety Regulation: UL1642, (UL file no.: MH21015), UN38.3
Liberty Premium 8
Liberty_Premium_English.indd 3
Liberty_Premium_English.indd 3
7.0-7.8
6-34°C (43-93°F)
Max 5,000 ppm
Max 4 ppm
50-60Hz
115W
IP 54
-10-60°C (discharging)
User Instructions
|
3
4/2/12 6:19 PM
4/2/12 6:19 PM