Gas Line Routing
Plan the routing of the gas line before proceeding.
Utilize the existing hole for the gas line. If the factory-
built fi replace has no access hole, carefully drill an
access hole of 1.5 inch (38 mm) or less through the
lower sides or bottom of the fi rebox. The access hole
must be plugged with non-combustible insulation after
the gas supply line has been installed. See Dimensions
section for detailed location of gas inlet. Also, take into
consideration whether or not a fan or shut-off valve will
interfere when planning routing of the gas line.
Existing Glass Doors and Wire Screens
Existing glass doors must be permanently removed
prior to installing the 739 insert.

Unpack the appliance

Beware of sharp edges! Wear gloves!
1. Unpack the appliance.
2. Unpack any loose items from around the appliance
and check against the Pack Content list provided in
the documentation package.
3. Remove the window and set aside in a safe place to
avoid damage—see next page.
4. Verify that you have all the components required
for the installation, including:
- fuel bed, fl uted panels & rocks;
- surround/doors/fret;
- venting components and accessories;
- blower and electrical components for blower
installation if used.
Existing Fireplace Preparation

Installation

Combustible Mantels
Combustible mantel clearances must conform to those
required for the original solid-fuel fi replace into which
the 739 is being installed.
Attach Warning Conversion Plate to Existing
Fireplace (label supplied loose with 739
heater)
Attach the "This fi replace has been converted..."
label to the existing fi replace using screws or other
mechanical means and store any removed parts in
back of the existing fi replace for future use.
QUALIFIED
INSTALLER