Advertisement

Product
Information
Promotional Video
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces
Sky T
Installation Manual
Gas Fireplaces
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un
installateur qualifié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
Sky
Sky T
October 2, 2015
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sky and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 Sky

  • Page 1 Installation Manual Sky T Product Sky T Information Promotional Video Gas Fireplaces HOT GLASS WILL Une surface vitrée chaude CAUSE BURNS. peut causer des brûlures. DO NOT TOUCH GLASS Laisser refroidir la surface UNTIL COOLED. vitrée avant d’y toucher. NEVER ALLOW CHILDREN Ne permettez jamais á...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information User Information Specifications and Dimensions Sky T Parts of the Fireplace Clearances Gas and Electric Venting Horizontal Vertical Enclosing the Fireplace Non- combustible Materials List Convection Air Opening Rough Opening Dimensions Operating the Fireplace...
  • Page 3: Important Safety Information

    Do not place furniture or other objects within 36” of the fireplace glass. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 Canada, consult with the local authority having jurisdiction for gas product installations to determine their The glass must only be removed by a qualified person. specific requirements for high altitude installations. Gloves should be worn when removing the glass. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 5 For convenience, the inches are rounded to the nearest 1/16” when converted. If greater accuracy is DO NOT USE abrasive cleaners on the panels. DO NOT required, use the metric dimensions. ATTEMPT to clean the glass panels when they are hot. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 6: User Information

    WARMTH AND BEAUTY - HOW IT WORKS The Element4 fireplaces are direct vent fireplaces and, as such, the intake and exhaust are both handled through the vent pipe. The fireplace also provides convection air to your room. The illustration shows one of the unique features of the Element4 fireplaces - its use of warm, convection air flow.
  • Page 7: Specifications And Dimensions

    SPECIFICATIONS and DIMENSIONS APPLIANCE RATINGS Model Sky T Natural Propane Input Maximum Btu/hr 44,500 37,380 Input Minimum Btu/hr 17,500 13,250 in. w.c. Maximum Supply Pressure 1.74 2.74 in. w.c. Minimum Supply Pressure in. w.c. 10.8 Manifold Pressure Maximum 0.99 2.68 in.
  • Page 8 Mantel / Linteau : 2” (5cm) Figure 3 Typical Rating Label A typical rating label is shown in Figure 3. It is attached to every Element4 fireplace and contains important certification information. It must not be removed from the fireplace.
  • Page 9 SPECIFICATIONS and DIMENSIONS Front Elevation Right Elevation Left Elevation Plan View Letter Inches Millimeters 271/8 3411/16 41/16 287/8 141/16 751/4 1911 681/2 1740 591/16 1500 125/16 145/16 711/16 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 10 SPECIFICATIONS and DIMENSIONS SKY T Front Elevation Right Elevation Left Elevation Plan View Letter Inches Millimeters 271/8 3411/16 41/16 287/8 165/16 751/4 1911 681/2 1740 591/16 1500 125/16 163/16 81/8 SKY T Element4 Gas Fireplaces EuropeanHome.com...
  • Page 11: Parts Of The Fireplace

    SPECIFICATIONS and DIMENSIONS PARTS OF THE FIREPLACE Parts of the Sky fireplace are shown in Figures 4, 5 and 6. These parts are also in the Sky T. Figure 4 Figure 5 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 12 Finish Trim - hides the Glass Clamps Interior Glass Panel (N/A - Sky, 1 - Sky T) Glass Clamp - holds the Glass Panel in place (6 ea. - Sky, 12 ea. - Sky T) Vent Collar - accepts the 5” x 8” venting adapter (included) Relief Door - part of the safety system.
  • Page 13: Clearances

    CLEARANCES MINIMUM CLEARANCE TO COMBUSTIBLES The Sky and Sky T fireplaces require non-combustible framing. These are NOT zero-clearance fireplaces. All clearances to • The appliance is approved with a minimum clearance to combustible AND non-combustible materials MUST be maintained combustible materials of 26”/660 11”/280...
  • Page 14 *drawings not to scale 26” 26” 660 mm 660 mm 11” 11” 11” 280 mm 280 mm 280 mm Figure 8 Front Elevation View - Sky Figure 9 Side Elevation View - Sky Element4 Gas Fireplaces EuropeanHome.com...
  • Page 15 *drawings not to scale 26” 660 mm 26” 660 mm 11” 11” 280 mm 280 mm Figure 11 Front Elevation View - Sky T Figure 12 Side Elevation View - Sky T Element4 Gas Fireplaces EuropeanHome.com...
  • Page 16 12”/300 mm MATERIAL Figure 14 CONSTRUCTION BEAMS NON- COMBUSTIBLE (TYPICAL) DETAIL C ETAIL C (1) 25 1”/25 mm GLASS ALE 1 : 10 TOP OF TOP OF FIREPLACE FIREPLACE OPENING OPENING GLASS Figure 13 CONVECTION GAP Element4 Gas Fireplaces EuropeanHome.com...
  • Page 17 Figure 15 Minimum Distances Convection Air Outlet Area by Model Room ceiling to 72” Square Square Model appliance bottom 1830 Inches Centimeters Room ceiling to top of 1” Convection Air Outlet Sky T Table 2 Table 3 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 18: Gas And Electric

    Table 4 ELECTRICAL REQUIREMENTS The Element4 fireplaces use a receiver and remote control for their burner operation. The remote control comes with (3) AAA batteries and the receiver is powered by a 120V AC adapter, included. The installer must provide an approved 120V AC wall receptacle to be placed within the six foot cord limit of the AC adapter.
  • Page 19: Venting

    A power vent system is available and must be used for any venting configuration which is outside of the vent graphs. For the M&G venting installation guide or power venting installation manuals please visit the link below. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 20 VENTING rise Figure 16 APPROVED MANUFACTURERS and COMPONENTS Manufacturer Components only DirectVent Pro® M&G DuraVent, Inc.* 5” x 8” venting components Table 5 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 21: Horizontal

    16’4”/5.0 m maximum depending on Dimension “V”. (See Graph 1) Dimension “V” (rise) can vary between 19”/500 minimum to 11’5”/3.5 m maximum depending on Dimension “H”. (See Graph 1) Note: Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 22 90° elbow, a total run of 13’2”/4.0 is allowed. Example B: If the rise is 8’2”/2.5 then the run can be no longer than 14’10”/4.5 Example C: If the run is 16’5”/5.0 then the rise must be at least 9’10”/3.0 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 23 VENTING HORIZONTAL HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 24: Vertical

    Power vent systems are available for configurations beyond these limits. Distance "V" 1m - 11m (min - max) Note: Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 18 Vertical Terminations with NO elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 25 Power vent systems are available for configurations beyond these limits. Distance "V" =2x "H" (min) Note: Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 19 Vertical Terminations with 90° elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 26 Power vent systems are available for configurations beyond these limits. Distance "V" =2x "H" (min) Note: Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Figure 20 Vertical Terminations with 45° elbows Element4 Gas Fireplaces EuropeanHome.com...
  • Page 27 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. Chart 1 Termination Heights A second termination may be no closer than 12”/305 . (See Figure 21) Figure 21 Multiple Termination Clearance Element4 Gas Fireplaces EuropeanHome.com...
  • Page 28 When vertical section is up to 391/2”/1 no restrictor required When vertical section is 391/2”/1 to 9’10”/3 restrictor -------------------------------------------------------------------------------------------------------------------------------------- When Using a Vertical (Roof) Termination When rise is up to 6’6”/2 When rise is above 6’6”/2 Figure 22 Figure 23 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 29: Enclosing The Fireplace

    ENCLOSING the FIREPLACE When enclosing your Element4 fireplace the use of non-combustible building materials is REQUIRED. Please read and understand the following. COMBUSTIBLE MATERIALS Materials that can catch fire and burn are considered combustible. Any material that is made of, or faced with, wood, wood pulp, paper, plastic or any other material that can catch fire and burn is considered combustible.
  • Page 30: Convection Air Opening

    1. Most important, these fireplaces are NOT zero-clearance fireplaces. Unlike zero-clearance fireplaces, there is not a metal box around the Element4 fireplaces. With no metal box there are no louvers to distract your view of the fire. However, we want the cooling advantage of a metal box so your site-built, non-combustible enclosure will substitute.
  • Page 31 ENCLOSING the FIREPLACE Sky/Sky T with End Wall Outlets Sky/Sky T with Outlet in Reveal Element4 Gas Fireplaces EuropeanHome.com...
  • Page 32 Any support framing must be at least 2”/50 (NON-combustible framing ONLY) above and beside the fireplace. The entire weight of the non-combustible walls must be borne by a structure other than the fireplace. Dimension A Dimension B Element4 Gas Fireplaces EuropeanHome.com...
  • Page 33: Rough Opening Dimensions

    ENCLOSING the FIREPLACE Rough Opening Dimensions for NON-COMBUSTIBLE Framing Model 3811/16”/990 185/16”/463 771/4”/1961 Sky T 3811/16”/990 203/16”/511 771/4”/1961 Table 6 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 34 LOCATING THE CONTROLS The control system for the Element4 fireplaces consist of three major components: the receiver, the transmitter and the gas valve. The transmitter is the remote control by which you operate the fireplace. The receiver and the gas control are at one end of a line set which will extend approximately 16”/406...
  • Page 35 One of the tie wraps which secure the line set. Figure 25 Wall Access Door Frame Figure 24 Tighten bolt through mounting bosses (at arrows) Fit tab into bracket on Access Door Figure 26 Figure 27 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 36 ENCLOSING the FIREPLACE Figure 28 Receiver in Wall Access Door Figure 29 Access Door Installed Element4 Gas Fireplaces EuropeanHome.com...
  • Page 37: Operating The Fireplace

    6. Place the three AAA batteries into the remote control and confirm that it will communicate with the receiver by pressing the ON/OFF. (See Figure 31) If necessary pair the remote and receiver. 7. Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote. THIS PART WAS INTENTIONALLY LEFT BLANK Element4 Gas Fireplaces EuropeanHome.com...
  • Page 38 Temp - Daytime Temperature mode. The appliance must be in standby mode, pilot ignited. The room temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to reach the daytime set temperature. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 39 2. The system shuts off the fire completely if there is no change in flame height for 5 days. 3. The system shuts off the fire if the main burner does not completely ignite approximately 20 seconds after ignition or after pushing the Ç button. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 40 Since it is a metal fireplace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your fireplace will keep these sounds to a minimum. To see an Element4 fireplace starting and running normally please visit the link below.
  • Page 41: Installing The Fire Media

    Figure 34. Ensure that the area inside the ember shield (circled) is left clear. Figure 34 Position the embers, coals and fir cones as shown in Figure 34. Figure 35 Position four of the larger logs as shown in Figure 35. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 42 The use of this ash is optional. To use: -Sprinkle the ash onto the logs as desired. -Make sure that the ash DOES NOT get inside of the burner ports. If so, clogging may occur. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 43: Stones

    2nd Thermocouple B shows the pilot area (arrow) clear of media. C shows the 2 thermocouple area (arrow) clear of media. To see how to arrange media in an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces...
  • Page 44: Screen Installation

    SCREEN INSTALLATION SKY T Magnets Magnets Long Screen Long Screen Place 3 magnets along each piece of vertical trim. As seen in the picture on the left, place 1 magnet in each corner and 1 in the middle on each vertical trim.
  • Page 45 SCREEN INSTALLATION Here is a close up of the magnet attached to the top corner of the vertical trim. Another view of the magnet location on the trim. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 46 SCREEN INSTALLATION Below shows a completed screen installation for the Sky. Please repeat the steps in this guide to install another screen on a Sky T. Above is a picture of the screen in place with a close up on the magnet between the screen and trim.
  • Page 47: Maintenance

    Step 1. Remove all of the trim pieces (magnetically attached) from the fireplace. (See Figure 38) The Sky T has two glass panels, therefore, twice the number of trim pieces. There is no top trim on either fireplace. The trim pieces are held firmly in place with magnets and will simply lift out.
  • Page 48 While ensuring that the glass panels are tight and square to each another, tighten the retaining bolt(s) on each clamp NO MORE THAN 1/4 TURN. PROPERLY PLACE, CLAMP AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE! Figure 41 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 49: Burner

    Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the manufacturer. Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the air flow. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 50: Thermocouple

    MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the main burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and not damaged.
  • Page 51: Warranty

    WARRANTY European Home Warranty Element4 Gas Fireplace European Home warrants these gas fireplaces against defects in materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase. Glass is expressly NOT covered by this warranty.
  • Page 52: Massachusetts Certification

    Gas Fitters has issued approval number G1-0515-495 for this appliance. The following must be observed when installing the Element4 fireplaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 53 No reaction to transmitter Do not coil the ignition cable. command. Shorten the ignition cable, if possible. Ignition sequence stops, no pilot flame. Replace receiver batteries. Quality 1.5V AA Transmitter command is possible. alkaline recommended. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 54 Check 2 thermocouple wiring. Replace transmitter batteries. Quality 1.5V Receiver batteries low. AA alkaline recommended. Magnet unit drops while motor turns. 3 beeps. Ground Bolt NORMAL OPERATION Figure 3.1 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 55 APPENDIX THREE Orifices and Shutters LP (PROPANE) CONVERSION APPLICABLE MODELS Figure 1. Bidore 100H, Modore 100H, Trisore 100H Sky, Sky T, 360, Lucius 70, Tenore 70 CONTENTS Shutter Bolts Supply Tube This LP conversion kit contains these instructions plus the following: •...
  • Page 56 Step 14: Connect the pilot burner inlet tube and tighten the inlet nut. Step 15: Insert the burner into the firebox and securely fasten with the bolts removed earlier. To see how to convert the gas on an Element4 fireplace, please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ EUROPEAN HOME •...
  • Page 57 • Increase the flame height: Press and hold the UP button. • Decrease the flame height: Press and hold the DOWN button. • For fine adjustment tap the UP or DOWN button as necessary. Figure 5.2 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 58 FIRST FIRE 40 WARRANTY 51 Lp 55 onverting to nstaLLing the ressures LISTING LABEL 8 LP (P ROPANE ONvERSION MAINTENANCE urner iLot herMocoupLes MANTELS 16 NON-COMBUSTIBLE MATERIALS iniMuM Learances Element4 Gas Fireplaces EuropeanHome.com...
  • Page 59 NOTES Element4 Gas Fireplaces EuropeanHome.com...
  • Page 60 Imported and distributed in North America by: EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington Street Suite 203 Malden, MA 02148 www.europeanhome.com IGE416-151002 Element4 Gas Fireplaces EuropeanHome.com...

This manual is also suitable for:

Sky t

Table of Contents