Table of Contents

Advertisement

Quick Links

I N S TA L L AT I O N M A N U A L
I N S TA L L AT I O N M A N U A L
S U M M U M 1 4 0 B I O
Please leave these instructions behind with the device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUMMUM 140 BIO and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 SUMMUM 140 BIO

  • Page 1 I N S TA L L AT I O N M A N U A L I N S TA L L AT I O N M A N U A L S U M M U M 1 4 0 B I O Please leave these instructions behind with the device...
  • Page 2 I N S T A L L A T I O N M A N U A L D O N O T U S E T H I S P R O D U C T A S A P R I M A R Y H E A T S O U R C E A L W A Y S U S E B I O E T H A N O L O F 8 5 % T O 9 6 , 6 % A L C O H O L...
  • Page 3: Table Of Contents

    I N S T A L L A T I O N M A N U A L TABLE OF CONTENTS CE STATEMENT � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 IMPORTANT INFORMATION �...
  • Page 4 I N S T A L L A T I O N M A N U A L MAINTENANCE INSTRUCTION � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �19 9�1 MAINTENANCE IN THE COMBUSTION CHAMBER �...
  • Page 5: Ce Statement

    CE STATEMENT IMPORTANT INFORMATION 2�1 SAFETY INFORMATION We hereby declare that the design and construction of the Element4 appliances are complying to the essential demands and regulations for The fireplace may only be installed by a qualified installer/dealer, gas products.
  • Page 6: Warranty

    In case the installer is not able to fix the problem himself, a request can be made to Element4 to do it for him, as long as the service can be done within the borders of the Benelux.
  • Page 7: Remote Control And Ignition

    Chapter 4 I N S T A L L A T I O N M A N U A L | REMOTE CONTROL AND IGNITION 4�1 REMOTE CONTROL 4�2 FILLING THE TANK Figure 4.1 The device is operated by remote control ( ) The remote control requires 4 type AAA batteries.
  • Page 8: Turning The Fire Place Off

    Chapter 4 I N S T A L L A T I O N M A N U A L | 4�4 TURNING THE FIRE PLACE OFF The tank hose can be emptied by pressing the -FILL- button several times while holding the hose upright to prevent spillage. Make To turn off the fire, touch the ON button to activate the remote control sure the hose is completely free of fuel before disconnecting it.
  • Page 9: Installation Preparation And Instruction

    I N S T A L L A T I O N M A N U A L | Chapter 5 INSTALLATION PREPARATION AND INSTRUCTION The device has been developed, tested and approved to conform with applicable standards for the usage, performance and safety of the product.
  • Page 10: Fire Safe Installation

    I N S T A L L A T I O N M A N U A L | Chapter 6 FIRE SAFE INSTALLATION To install a bioathanol fireplace as safely as possible, several installation preparations need to be made. This overview can be used to assure the fire safety of a conversion of a fireplace.
  • Page 11 I N S T A L L A T I O N M A N U A L | Chapter 6 Figure 6.1 | C11: Flue situation Non-Flammable materials Figure 6.3 | C11: Flue situation Flammable materials Figure 6.2 | C31: Flue situation Non-Flammable materials Figure 6.4 | C31: Flue situation Flammable materials...
  • Page 12: Other Rules Regarding Heat In Your Installation

    6�3�4 OUTDOOR INSTALLATION This appliance is meant for indoor use. In the case that an Element4 6�3�2 CONVECTION appliance is to be installed as part of an indoor outdoor construction,...
  • Page 13: Chimney Construction For The Summum 140 4S

    I N S T A L L A T I O N M A N U A L | Chapter 6 6�3�5 CHIMNEY CONSTRUCTION FOR THE SUMMUM 140 4S Step 3: This instruction is intended for the Summum 140 4S and is a supplement Make a load-bearing construction of non-combustible materials on the to the general safety requirements for installing a gas fire, as mentioned support profiles on the top of the fireplace.
  • Page 14 I N S T A L L A T I O N M A N U A L Figure 6.9 | Remove transport brackets Figure 6.8 | Loosening transport brackets Figure 6.10 | Insert Side Window Figure 6.11 | Position of the transport brackets...
  • Page 15 I N S T A L L A T I O N M A N U A L Figure 6.12 | Figure 6.13 | Create a frame on top of the fireplace Create another frame on the ceiling Figure 6.14 | Figure 6.15 | Align both the frames Adding vertical insert between the frames...
  • Page 16 I N S T A L L A T I O N M A N U A L Figure 6.16 | Complete base of the frame Figure 6.17 | Final result with additional crossbars Figure 6.18 | Construction of fireproof material Figure 6.19 | Final construction of the chimney breast...
  • Page 17: Attention Points Flue Gas Extraction

    I N S T A L L A T I O N M A N U A L | Chapter 7 ATTENTION POINTS FLUE GAS EXTRACTION 7�3 BENDS To guarantee the fire safety regarding you flue gas configuration a casing Be aware of the bends in your flue.
  • Page 18: Calculate Flue Length

    I N S T A L L A T I O N M A N U A L | Chapter 7 7�3�1 CALCULATE FLUE LENGTH Not all parts can be adjusted! To fit the drainage system correctly, you are to use an adjustable fitting. You can use an adjustable concentric pipe, wall or roof fitting.
  • Page 19: Safety

    I N S T A L L A T I O N M A N U A L | Chapter 8 SAFETY The Element4 bioethanol fireplace has several safety systems to ensure that it can be used in the safest way. Nevertheless, a few things must be taken into account: •...
  • Page 20: Maintenance Instruction

    I N S T A L L A T I O N M A N U A L | Chapter 9 MAINTENANCE INSTRUCTION This part of the manual focuses on maintenance. To ensure the optimal flame picture of your device, an annual maintenance by a competent company or installer is prescribed.
  • Page 21 I N S T A L L A T I O N M A N U A L Figure 9.2 | Figure 9.5 | Remove side trims Using the suction cup Figure 9.3 | Figure 9.6 | Remove Lower Trims Removing the glass pane Figure 9.4 | Figure 9.7 |...
  • Page 22: 9�1�3 (Dis)Assembly Of The Trims - Summum 140 Rd & T

    I N S T A L L A T I O N M A N U A L | Chapter 9 9�1�3 (DIS)ASSEMBLY OF THE TRIMS - SUMMUM 140 RD & T 9�1�4 REMOVE GLASS For a tight finish of the fireplace, trims are available. During maintenance To be able to cleam the glass on the inside, one needs to remove the these trims must be removed, before the glass can be removed (see glass.
  • Page 23 I N S T A L L A T I O N M A N U A L Figure 9.9 | Figure 9.12 | Remove side trims Put on the suction cup Figure 9.10 | Figure 9.13 | Remove bottom trim Remove glass Figure 9.11 | Remove glass clamps...
  • Page 24: 9�1�5 Mounting And Dismantling Cover Strips Summum 140 4S

    I N S T A L L A T I O N M A N U A L | Chapter 9 9�1�5 MOUNTING AND DISMANTLING COVER STRIPS SUMMUM 140 4S 9�1�6 REMOVE GLASS FROM THE SUMMUM 140 4S Figure 9.14 Decorative trims are available for finishing the fireplace (See attention! When the chimney breast is fully and correctly installed, .
  • Page 25 I N S T A L L A T I O N M A N U A L Figure 9.15 | Remove trims Figure 9.18 | Removal of long side glass Figure 9.16 | Figure 9.19 | Remove glass clamps on the sides Take out glass clamps for the side windows Figure 9.17 | Put on the suction cups...
  • Page 26: Decorative (Ceramic) Parts

    Only the decoration ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown on this page. Replacement parts are available from your dealer, but should only be installed by a qualified installation engineer. Figure 10.1 | Logset Summum 140 Bio...
  • Page 27 I N S T A L L A T I O N M A N U A L | Chapter 10 Take a small portion of the supplied Premium Glow material and stretch Figure 10.2 | Adding Premium glow it into long, thin strands. Carefully position the strands over the burner inside the orange box, ensuring they do not come into contact with any of the sensors.
  • Page 28 I N S T A L L A T I O N M A N U A L | Chapter 10 Place the logs as shown above. Figure 10.4 | Add logs Place the logs as shown above. Figure 10.5 | Add logs...
  • Page 29 I N S T A L L A T I O N M A N U A L | Chapter 10 Place gray and black chips around the logs, partly covering the glass. Figure 10.6 | Add gray and black chips Make sure that none of the chips fall into the burner.
  • Page 30: Operating The Fireplace

    I N S T A L L A T I O N M A N U A L | Chapter 11 OPERATING THE FIREPLACE 11�1 BEFORE THE FIRST FIRE 11�3�2 SMELL CHECK When the fireplace is first heated, an odour may be given off by the hot Make certain that all construction materials have been removed metal.
  • Page 31: Atroubleshooter

    I N S T A L L A T I O N M A N U A L | Appendix A TROUBLESHOOTER A�A FIRST AID FOR MALFUNCTION Below you will find an overview of the possible cause and solution in the event of a failure.
  • Page 32: A�Bnecessary Tools

    If a problem is found, that cannot be solved on site, always contact your Element4 expects are being carried during said services. dealer or directly contact Element4 via our credentials which can be When all these tools are available during service, Element4 guarantees found on the back page of this manual.
  • Page 33: Bterminal Location

    I N S T A L L A T I O N M A N U A L | Appendix B TERMINAL LOCATION B�B TERMINAL LOCATION WITH HORIZONTAL EXHAUST (C31) B�A TERMINAL LOCATION WITH VERTICAL EXHAUST (C11) Distance Exhaust 1,2 of 3 Position terminal dist.
  • Page 34: Cerror Codes

    I N S T A L L A T I O N M A N U A L | Appendix C ERROR CODES C�A MESSAGES SHOWN ON REMOTE CONTROL The installed software will give an error/stop code if the bioethanol fire has stopped or not started for any reason.
  • Page 35 I N S T A L L A T I O N M A N U A L | Appendix C Erro code Description Possible causes Possible solutions Time out, waiting • The fuel did not reach the high sensor in •...
  • Page 36: Dtechnical Data

    Note: Always use Bio-Ethanol with 85% to 96.6% alcohol. If in doubt, contact your dealer. Values for Summum 140 bio - all models GROSS output on HIGH* Consumption on HIGH GROSS output on MEDIUM...
  • Page 37: Eecodesign

    E�A ECOLABEL Below is the ecolabel for the Summum 140 Bio. There are two installation options: flueless or balanced flue. For a flueless installation, the efficiency is 100% because all the heat remains in the installation area.
  • Page 38: Fdimensional Drawings

    I N S T A L L A T I O N M A N U A L | Appendix F DIMENSIONAL DRAWINGS On this page you will find trhr dimensional drawings of the different configurations with some of the important dimensions that you have to take into account when installing and installing your fireplace.
  • Page 39 I N S T A L L A T I O N M A N U A L | Appendix F Fire view opening 427 ext. adjustable Frame Figure F.B | Technical drawing of Summum 140 C...
  • Page 40 I N S T A L L A T I O N M A N U A L | Appendix F Fire view opening 429 ext. adjustable Frame Figure F.C | Technical drawing of Summum 140 3S...
  • Page 41 I N S T A L L A T I O N M A N U A L | Appendix F 16 5 " Fire view opening 16 15 " " ext. " adjustable Frame " 33 9 " Figure F.D | Technical drawing of Summum 140 RD...
  • Page 42 I N S T A L L A T I O N M A N U A L | Appendix F Fire view opening 430 ext. 98,5 adjustable Frame Figure F.E | Technical drawing of Summum 140 T...
  • Page 43 I N S T A L L A T I O N M A N U A L | Appendix F Fire view opening 430 ext. 153,5 adjustable Figure F.F | Technical drawing of Summum 140 4S...
  • Page 44 Design & Assembly by: E L E M E N T 4 B . V. Info@element4.nl www.element4fires.com 0 7 / 0 3 / 2 5 RELEASE DATE |...

Table of Contents