Information
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces
Sky T
Video
Installation, Operation and
Owner's Manual

Direct Vent

Gas Fireplaces
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un
installateur qualifié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006611
Sky
Sky T
January 22, 2016
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sky and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 Sky

  • Page 1: Direct Vent

    Installation, Operation and Owner’s Manual Sky T Product Sky T Information Video Direct Vent Gas Fireplaces HOT GLASS WILL Une surface vitrée chaude CAUSE BURNS. peut causer des brûlures. DO NOT TOUCH GLASS Laisser refroidir la surface UNTIL COOLED. vitrée avant d’y toucher.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information User Information Specifications and Dimensions Sky T Parts of the Fireplace Clearances Gas and Electric Venting Horizontal Vertical Enclosing the Fireplace Non- combustible Materials List Building the Enclosure Convection Air Opening Operating the Fireplace...
  • Page 3: Important Safety Information

    Do not place furniture or other objects within 36” of the fireplace glass. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 Canada, consult with the local authority having jurisdiction for gas product installations to determine their The glass must only be removed by a qualified person. specific requirements for high altitude installations. Gloves should be worn when removing the glass. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 5 For convenience, the inches are rounded to the nearest 1/16” when converted. If greater accuracy is DO NOT USE abrasive cleaners on the panels. DO NOT required, use the metric dimensions. ATTEMPT to clean the glass panels when they are hot. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 6: User Information

    WARMTH AND BEAUTY - HOW IT WORKS The Element4 fireplaces are direct vent fireplaces and, as such, the intake and exhaust are both handled through the vent pipe. The fireplace also provides convection air to your room. The illustration shows one of the unique features of the Element4 fireplaces - its use of warm, convection air flow.
  • Page 7: Specifications And Dimensions

    SPECIFICATIONS and DIMENSIONS APPLIANCE RATINGS Model Sky T Natural Propane Input Maximum Btu/hr 44,500 37,380 Input Minimum Btu/hr 17,500 13,250 in. w.c. Maximum Supply Pressure 1.74 2.74 in. w.c. Minimum Supply Pressure in. w.c. 10.8 Manifold Pressure Maximum 0.99 2.68 in.
  • Page 8 Floor / Sol : 4” (10cm) Mantel / Linteau : 2” (5cm) A typical rating label is shown above. It is attached to every Element4 fireplace and contains important certification information. It must not be removed from the fireplace. Element4 Gas Fireplaces...
  • Page 9 SPECIFICATIONS and DIMENSIONS Front Elevation Right Elevation Left Elevation Plan View Letter Inches Millimeters 271/8 3411/16 41/16 287/8 141/16 751/4 1911 681/2 1740 591/16 1500 125/16 145/16 711/16 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 10 SPECIFICATIONS and DIMENSIONS SKY T Front Elevation Right Elevation Left Elevation Plan View Letter Inches Millimeters 271/8 3411/16 43/16 287/8 165/16 751/4 1911 681/2 1740 591/16 1500 125/16 163/16 83/16 SKY T Element4 Gas Fireplaces EuropeanHome.com...
  • Page 11: Parts Of The Fireplace

    SPECIFICATIONS and DIMENSIONS PARTS OF THE FIREPLACE Parts of the Sky fireplace are shown following. These parts are also in the Sky T. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 12 Finish Trim - hides the Glass Clamps Room Air Inlet (hidden) Glass Clamp - holds the Glass Panel in place (6 ea. - Sky, 12 ea. - Sky T) Vent Collar - accepts the 5” x 8” venting adapter (included) Relief Door - part of the safety system.
  • Page 13: Clearances

    ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT IMPEDE THE FULL OPERATION OF THE RELIEF DOORS (if applicable). IT IS YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION PROCESS. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 14 26” *drawings not to scale 26” 660 mm 660 mm 11” 11” 11” 280 mm 280 mm 280 mm Front Elevation View - Sky Side Elevation View - Sky Element4 Gas Fireplaces EuropeanHome.com...
  • Page 15 1/8”/3 vertical clearance to allow for heat expansion. 26” 660 mm 26” *drawings not to scale 660 mm 11” 11” 280 mm 280 mm Side Elevation View - Sky T Front Elevation View - Sky T Element4 Gas Fireplaces EuropeanHome.com...
  • Page 16 NOT PERMITTED IN FRONT OF GLASS CONSTRUCTION BEAMS COMBUSTIBLE (TYPICAL) Mantel Depth NON COMBUSTIBLE 12”/300 mm MATERIAL CONSTRUCTION BEAMS NON- COMBUSTIBLE (TYPICAL) DETAIL C ETAIL C 1”/25 mm ALE 1 : 10 TOP OF FIREPLACE OPENING GLASS CONVECTION GAP Element4 Gas Fireplaces EuropeanHome.com...
  • Page 17 The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 Convection Air Outlet Minimum Distances Convection Air Outlet Area by Model Room ceiling to 72” Square Square Model appliance bottom 1830 Inches Centimeters Room ceiling to top of 1” Convection Air Outlet Sky T Element4 Gas Fireplaces EuropeanHome.com...
  • Page 18: Gas And Electric

    ELECTRICAL REQUIREMENTS The Element4 fireplaces use a receiver and remote control for their burner operation. The remote control comes with (3) AAA batteries and the receiver is powered by a 120V AC adapter, included. The fireplace should be powered by the AC adapter for improved reliability and customer satisfaction.
  • Page 19: Venting

    Your venting needs to be inspected annually, including any connected components, to ensure that the system is working as designed. For the M&G venting installation guide or power venting installation manuals please visit the link below. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 20 VENTING rise APPROVED MANUFACTURERS and COMPONENTS Manufacturer Components only DirectVent Pro® M&G DuraVent, Inc.* 5” x 8” venting components Element4 Gas Fireplaces EuropeanHome.com...
  • Page 21: Horizontal

    11’5”/3.5 m maximum depending on Dimension “H”. Refer to the Horizontal Termination Graph, below. Power vent systems are available for configurations beyond these limits Note! Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 22 Example B: With a total rise of 6’6”/2.0 and two horizontal 90° elbows, a total run of 9’10”/3.0 is allowed. and three horizontal 90° elbows, a total run of 6’6”/2.0 Example C: With a total rise of 6’6”/2.0 is allowed. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 23 VENTING HORIZONTAL HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 24: Vertical

    Power vent systems are available for configurations beyond these limits. Distance "V" 1m - 11m (min - max) Note! Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 25 Distance "V" =2x "H" (min) Power vent systems are available for configurations beyond these limits. Note! Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 26 Distance "V" (= V1+V2+V3) = 1.2m - 11m (min - max) Power vent systems are available for configurations beyond these limits. Distance "V" =2x "H" (min) Note: Configurations with vertical terminations may need a restrictor. See the INSTALLING A RESTRICTOR section. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 27 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. Termination Heights A second termination may be no closer than 12”/305 Multiple Termination Clearance Element4 Gas Fireplaces EuropeanHome.com...
  • Page 28 When vertical section is greater than 3’3”/1 restrictor -------------------------------------------------------------------------------------------------------------------------------------- When Using a Vertical (Roof) Termination When rise is up to 6’6”/2 When rise is greater than 6’6”/2 35 mm restrictor (left) and 60 mm restrictor 35 mm restrictor in place Element4 Gas Fireplaces EuropeanHome.com...
  • Page 29: Enclosing The Fireplace

    ENCLOSING the FIREPLACE When enclosing your Element4 fireplace the use of non-combustible building materials is REQUIRED. Please read and understand the following. COMBUSTIBLE MATERIALS Materials that can catch fire and burn are considered combustible. Any material that is made of, or faced with, wood, wood pulp, paper, plastic or any other material that can catch fire and burn is considered combustible.
  • Page 30: Building The Enclosure

    1. Most important, these fireplaces are NOT zero-clearance fireplaces. Unlike zero-clearance fireplaces, there is not a metal box around the Element4 fireplaces. With no metal box there are no louvers to distract your view of the fire. However, we want the cooling advantage of a metal box so your site-built, non-combustible enclosure will substitute.
  • Page 31 When enclosing the Sky T fireplace there is a minimum clear area which must be maintained. Nothing except the Sky T may be within this area. When enclosed, the Sky T is centered - left to right and front to back - within this minimum area, above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL.
  • Page 32 When enclosing the Sky fireplace there is a minimum clear area which must be maintained. Nothing except the Sky may be within this area. When enclosed, the Sky is centered - left to right and front to back - within this minimum area, above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL.
  • Page 33 ENCLOSING the FIREPLACE SKY/SKY T The finished wall(s) must be at least 11/8”/28 thick or the fireplace trim will extend beyond the finished wall. The list below shows the thickness of the approved wall products. Your choice of wall material depends largely on the intended finish. For example, a thinner wall product and a layer of stone may be thick enough to reach the trim edge.
  • Page 34: Convection Air Opening

    Shown here are a number of ways to design the convection air outlet into your project. Convection Air Outlet Area by Model Sky/Sky T with End Wall Outlets Square...
  • Page 35 Any support framing (NON-combustible framing ONLY) must be at least 2”/50 above and beside the fireplace. The entire weight of the non- combustible walls must be borne by a structure other than the fireplace. Dimension A Dimension B Element4 Gas Fireplaces EuropeanHome.com...
  • Page 36 It also helps to tape the venting for maximum air tightness and to caulk firestops. LOCATING THE CONTROLS The control system for the Element4 fireplaces consist of three major components: • the receiver •...
  • Page 37 Replace the white door/frame cover onto the radius of less than 2”/50 frame and secure it with the four bolts. Fit the gas control tab into the bracket on Tighten the bolt through the mounting bosses. the Access Door frame. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 38 Once the system stays lit for at least one full minute, turn the fireplace off, fix the glass panels in place and operate the fireplace for at least 45 minutes to ensure the system works properly when heated. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 39: Operating The Fireplace

    2nd thermocouple (circled) is remains clear of embers. With the embers scattered across the burner and hearth panel, lay the logs in the following sequence... (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 40 INSTALLING THE FIRE MEDIA (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 41 The use of this ash is optional. To use: - Sprinkle the ash onto the logs as desired. - Keep the ash away from the burner as clogging of the burner openings may occur. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 42 B shows the pilot area (below) clear of media (above). C shows the 2 thermocouple area (below) clear of media (above). 2nd Thermocouple Pilot Assembly To see how to arrange media in an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 43: Installing The Fire Media

    & on when the fireplace is turned on.) Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 44 The appliance must be in standby mode, pilot ignited. The room temperature is measured and compared to the nighttime setback temperature. The flame height is then automatically adjusted to achieve the nighttime setback temperature. next burner Temp cycle. Press OFF to complete the program. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 45 2. The system shuts off the fire completely if there is no change in flame height for 5 days. 3. The system shuts off the fire if the main burner does not completely ignite approximately 20 seconds after ignition or after pushing the Ç button. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 46: Stones

    Since it is a metal fireplace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your fireplace will keep these sounds to a minimum. To see an Element4 fireplace starting and running normally please visit the link below.
  • Page 47: Screen Installation

    SCREEN INSTALLATION SKY T Magnets Magnets Long Screen Long Screen Place 3 magnets along each piece of vertical trim. As seen at left, place 1 magnet in each corner and 1 in the middle on each vertical trim. Element4 Gas Fireplaces...
  • Page 48 SCREEN INSTALLATION Here is a close up of the magnet attached to the top corner of the vertical trim. Another view of the magnet location on the trim. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 49 SCREEN INSTALLATION Shown below is a completed screen installation for the Sky. Repeat the steps in this guide to install another screen on a Sky T. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 50: Maintenance

    Step 1. Remove all of the trim pieces (magnetically attached) from the fireplace. The Sky T has two glass panels, therefore, twice the number of trim pieces. There is no top trim on either fireplace. The trim pieces are held firmly in place with magnets and will simply lift out.
  • Page 51 While ensuring that the glass panels are tight and square to each another, tighten the retaining bolt(s) on each clamp NO MORE THAN 1/4 TURN. PROPERLY PLACE, CLAMP AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE! Element4 Gas Fireplaces EuropeanHome.com...
  • Page 52: Burner

    The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum. Pilot Injector Natural - Marking 31.2 Pilot Injector Propane - Marking 27.1 Thermocouple Ignitor Rod Thermocouple Pilot Assembly Ignitor Rod (styles vary) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 53: Thermocouple

    MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the main burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and not damaged. While checking the thermocouple, please ensure that the ignitor rod is not cracked as well.
  • Page 54: Warranty

    WARRANTY European Home Warranty Element4 Gas Fireplace European Home warrants these gas fireplaces against defects in materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase. Glass is expressly NOT covered by this warranty.
  • Page 55: Massachusetts Certification

    Gas Fitters has issued approval number G1-0515-495 for this appliance. The following must be observed when installing the Element4 fireplaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 56 No reaction to transmitter Do not coil the ignition cable. command. Shorten the ignition cable, if possible. Ignition sequence stops, no pilot flame. Replace receiver batteries. Quality 1.5V AA Transmitter command is possible. alkaline recommended. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 57 Check 2 thermocouple wiring. Replace transmitter batteries. Quality 1.5V Receiver batteries low. AA alkaline recommended. Magnet unit drops while motor turns. 3 beeps. Ground Bolt NORMAL OPERATION Element4 Gas Fireplaces EuropeanHome.com...
  • Page 58 APPENDIX THREE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 59 APPENDIX THREE To see how to convert the gas on an Element4 fireplace, please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 60 Increase the flame height: Press and hold the UP button. • Decrease the flame height: Press and hold the DOWN button. • For fine adjustment tap the UP or DOWN button as necessary. • Turn fireplace OFF: Press the ON/OFF button. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 61 NOTE Frequent ON and OFF cycles will limit life expectancy of the valve and will increase battery consumption. The fireplace should be powered by the AC adapter for improved reliability and customer satisfaction. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 62 FIRST FIRE 42 WARRANTY 54 Lp 56 onverting to nstaLLing the ressures LISTING LABEL 8 LP (P ROPANE ONvERSION MAINTENANcE urner Lass iLot herMocoupLes MANTELS 16 NON-cOMBUSTIBLE MATERIALS iniMuM Learances Element4 Gas Fireplaces EuropeanHome.com...
  • Page 63 NOTES Element4 Gas Fireplaces EuropeanHome.com...
  • Page 64 Imported and distributed in North America by: EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington Street Suite 203 Malden, MA 02148 www.europeanhome.com IGE416-160122 Element4 Gas Fireplaces EuropeanHome.com...