Table of Contents

Advertisement

Quick Links

INSTALLATION MANUAL
S U M M U M 1 0 0
P L E A S E L E AV E T H E S E I N ST R U CT I O N S B E H I N D W I T H T H E D E V I C E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUMMUM 100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 SUMMUM 100 Series

  • Page 1 INSTALLATION MANUAL S U M M U M 1 0 0 P L E A S E L E AV E T H E S E I N ST R U CT I O N S B E H I N D W I T H T H E D E V I C E...
  • Page 2 I N STA L L AT I O N M A N UA L...
  • Page 3 I N STA L L AT I O N M A N UA L D O N OT US E T H I S P R O D U CT A S A P R I M A RY H E AT S O U R C E...
  • Page 4 I N STA L L AT I O N M A N UA L...
  • Page 5: Table Of Contents

    8 INSTALLATION CHECK AND FIRST USAGE 8.1 Renovation/new construction 8.2 Checking the gas lines 9 ELECTRICAL CIRCUIT 9.1 Domotica 9.2 Element4 ProControl App. 10 MAINTENANCE INSTRUCTION 10.1 Maintenance in the combustion chamber 10.2 Cleaning the glass 11 DECORATION ARRANGEMENT 12 USER INSTRUCTION 12.1 Hand over to the customer...
  • Page 6: Ce Statement

    This declaration loses its validity when changes to the device are is broken. The flue gasses can get into the installation room. The made without the written permission by Element4. You can ask settings and construction of the device must not be changed! for a copy of the test certificates of all models via our general e-mail adress, which is found on the back of this manual.
  • Page 7: Warranty

    In case the installer is not able to fix the problem himself, a request can be made to Element4 to do it for him, as long as the service can be done within the borders of the Benelux.
  • Page 8: Remote Control With Full Electronic Ignition

    4 REMOTE CONTROL WITH FULL ELECTRONIC IGNITION 4.1) or the The unit is operated using a remote control (Fig. Element4 Puck, connected to a receiver (Fig. 4.2). The receiver is powered by 4 pen lite (type AA) batteries or a 6V adapter;...
  • Page 9: Installation Preparation And - Instruction

    85 C. Use the ventilation grate (CVRE4) and service hatch 5.4 Requirements flue and wall terminals (BDLE4) by Element4. See the measurements in APPENDIX I More on chimney construction in The European CE-marking for the device is only applicable to THE NEXT CHAPTER.
  • Page 10: Fire Safe Installation

    I N STA L L AT I O N M A N UA L 6 FIRE SAFE INSTALLATION To install a gas fireplace as safely as possible, several installation preparations need to be made. This overview can be used to assure the fire safety of a conversion of a fireplace.
  • Page 11: Assembly Regulations With Flammable Materials

    I N STA L L AT I O N M A N UA L 6.3 Assembly regulations with flammable materials (Figure 6.3 and 6.4) Load-bearing walls and ceilings must be covered in a protective fire resistant plate. Never use flammable materials around the fireplace or cove. The minimal distance between the device and non-flammable materials must be at 50 mm to ensure a convection air flow.
  • Page 12: Attention Points Gas Flue

    I N STA L L AT I O N M A N UA L 7 ATTENTION POINTS GAS FLUE 8 INSTALLATION CHECK AND FIRST USAGE 8.1 Renovation/new construction To guarantee the fire safety regarding you flue gas configuration a casing is necessary. For this case non-combustible materials should be used.
  • Page 13: Electrical Circuit

    Every fireplace is provided with a main adapter. adjusted for Element4 devices. Up to eight devices can be used with one app, in the situation that multiple fire are installed in the same location.
  • Page 14: Maintenance Instruction

    Use cleaning supplies qualified by Element4. • When you clean your Anti-Reflective glass, make sure you use this with the special Element4 cleaner, which is available only via Element4. • Use only a microfibre cloth. Other materials such as kitchen towels, steel wool etcetera can cause scratches or damage the coating on the glass.
  • Page 15 I N STA L L AT I O N M A N UA L Figure 10.2 - Remove upper screws Figure 10.6 - Remove glass cords Figure 10.3 - Remove upper trim Figure 10.7 - Put on the front window Figure 10.4 - Remove side trims Figure 10.8 - Remove front window Figure 10.5 - Remove bottom trim...
  • Page 16: Decoration Arrangement

    I N STA L L AT I O N M A N UA L 11 DECORATION ARRANGEMENT Position the decoration logs as shown on the image below. Only the decoration ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown on this page. Make sure that the pilot flame area and the second thermocouple Replacement parts are available from your dealer, but should are always free of any decorative material to make certain that...
  • Page 17 Note: The 12V adapter that comes with the LED Module is to be plugged into the LED module itself! This is contrary to other Element4 fireplaces that feature a 6V plug which is put into the receiver!
  • Page 18: User Instruction

    (sanding) sponges, abrasives and cleaning agents with ammonia is prohibited. Only use a neutral cleaning product 13.1 Hand over to the customer (neither acidic nor alkaline), such as Element4 window cleaner (Item No. 4500926). The cleaning agents that you normally use •...
  • Page 19 I N STA L L AT I O N M A N UA L A P P E N D I C E S...
  • Page 20: A First Aid For Malfunction

    A P P E N D I C E S A FIRST AID FOR MALFUNCTION Below you will find an overview of the possible cause and solution in the event of a failure. Problem Possible Cause Solution No transmission 1 Batteries in the receiver empty Replace the batteries (4x 1.5V AA) (motor will not 2 Batteries hand remote empty...
  • Page 21 A P P E N D I C E S 4,5 mV 4,5 mV 4,5 mV 4,5 mV Figure A-1: Bend pin Figure A-4: Testpoint A Figure A-5: interrupter Figure A-2: Antenna Figure A-6: Wiring receiver Figure A-7: Pilot set Figure A-3: Torx screw...
  • Page 22 A P P E N D I C E S Problem Possible Cause Solution The pilot light goes 1 Insufficient voltage across the thermocouple or Place the measuring pins of the multimeter on the ground and on but goes out too much resistance in the thermocouple circuit black cable of the breaker.
  • Page 23 A P P E N D I C E S Figure A.8: Second thermocouple Figure A.11: “Double plus”-button on the remote Figure A.9: Button A on “On” Figure A.13: SI-port Figure A.10: RESET-button Figure A.11: Aux-position receiver Figure A.14: Domotica system...
  • Page 24: B Errors Codes Procontrol App

    A P P E N D I C E S B ERRORS CODES PROCONTROL APP B.1 Messages shown in app Error Message in App Description Possible cause code Contact Service. • 5 sec. beep from Receiver • Microswitch not making contact with cam on motor knob •...
  • Page 25 A P P E N D I C E S Error Message in App Description Possible cause code Contact Service. • Fire is not responding • Receiver or Wi-Fi Box malfunction • No electronic control of fire • Connection cable from Receiver to Wi-Fi Box defective Check Wi-Fi •...
  • Page 26: C Faults And Error Codes In The Remote

    A P P E N D I C E S C FAULTS AND ERROR CODES IN THE REMOTE This appendix can be consulted when error messages occur in the application for smartphone and tablet. C.1 F41 error This message will appear if there is no or bad Wi-Fi reception, this can be between app and router or Wi-Fi box and router By closing the App and opening it again, this is solved in most cases.
  • Page 27: D Location Terminal

    A P P E N D I C E S D LOCATION TERMINAL D.1 Terminal location with vertical exhaust (C11) D.2 Terminal location with Horizontal exhaust (C31) Distance Exhaust 1,2 of 3 Position terminal dist. (mm) At the same roof level >...
  • Page 28: E General Rules For Flue Gas Extraction

    A P P E N D I C E S E GENERAL RULES FOR FLUE GAS EXTRACTION E.1 Power-Fan For flue configurations that do not function on natural draft , the PowerFan can be used. For extensive installation instructions and the operation of the PowerFan we refer to the manual of the PowerFan.
  • Page 29: F Calculation Table Flue Gas Reduction

    A P P E N D I C E S F CALCULATION TABLE FLUE GAS REDUCTION The calculation table shows when you need to place a flue gas ristrictor Result Action No ristrictor required √ Position the resitrictor No good operation guaranteed * F.1 Horizontal terminal flue diameter F.2 Vertical terminal flue diameter For a vertical terminal the minimal starting length is 0,5 meter...
  • Page 30: G Technical Data

    A P P E N D I C E S G TECHNICAL DATA The dataplate specifies for which type of gas, gas pressure and for which country this appliance is intended. The nameplate is attached to a chain. It must remain attached to the chain. Note: Check whether the appliance is suitable for the gas type and gas pressure on site.
  • Page 31: H Ecodesign

    A P P E N D I C E S H ECODESIGN Since 1 January 2018 every fireplace has been provided with an eco-label which is always supplied with the fireplace. The ecolabel shows which category the fireplace belongs to. H.1 Ecolabels The ecolabels for the different types of gas are indicated below, respectively G20, G25 and G30.
  • Page 32: I Dimensional Drawings

    A P P E N D I C E S I DIMENSIONAL DRAWINGS On this page and the following ones you will find dimensional drawings of the Summum 100 models and accessories with some of the important dimensions that you have to take into account when installing and installing your fireplace.
  • Page 33 A P P E N D I C E S 199,00 119,05 134,00 1000,00 51,50 51,50 64,00 1008,00 1091,00 I.2 - Technical drawing of Summum 100 F...
  • Page 34 A P P E N D I C E S 199,00 119,05 119,05 134,00 328,00 1000,00 51,50 51,50 66,57 61,50 62,00 1047,00 1102,00 Figure I.1 - Technical drawing of Summum 100 C...
  • Page 35 A P P E N D I C E S 199,00 119,05 134,00 328,00 1000,00 51,50 66,57 61,50 62,00 1116,00 I.2 - Technical drawing of the Summum 100 3S...
  • Page 36 E L E M E N T 4 B .V. Paxtonstraat 23 8013 RP Zwolle The Netherlands Info@element4.nl www.element4fires.com R E L E A S E DAT E | 0 3 / 0 9 / 1 9...

This manual is also suitable for:

Summum 100 fSummum 100 cSummum 100 3s

Table of Contents