8 INSTALLATION CHECK AND FIRST USAGE 8.1 Renovation/new construction 8.2 Checking the gas lines 9 ELECTRICAL CIRCUIT 9.1 Domotica 9.2 Element4 ProControl App. 10 MAINTENANCE INSTRUCTION 10.1 Maintenance in the combustion chamber 10.2 Cleaning the glass 11 DECORATION ARRANGEMENT 12 USER INSTRUCTION 12.1 Hand over to the customer...
This declaration loses its validity when changes to the device are data plate at the time of purchase. made without the written permission by Element4. You can ask for a copy of the test certificates of all models via our general The device may never be used without the glass of when glass e-mail adress, which is found on the back of this manual.
In case the installer is not able to fix the problem himself, a request can be made to Element4 to do it for him, as long as the service can be done within the borders of the Benelux.
4 REMOTE CONTROL WITH FULL ELECTRONIC IGNITION 4.1) or the The unit is operated using a remote control (Fig. Element4 Puck, connected to a receiver (Fig. 4.2). The receiver is powered by 4 pen lite (type AA) batteries or a 6V adapter;...
C. Use the ventilation grate (CVRE4) and service hatch Before installation of these appliances, the area into which the (BDLE4) by Element4. See the measurements in fire is to be fitted must be cleared of all debris (including dust), in APPENDIX I particular combustible material.
I N STA L L AT I O N M A N UA L 6 FIRE SAFE INSTALLATION To install a gas fireplace as safely as possible, several installation preparations need to be made. This overview can be used to assure the fire safety of a conversion of a fireplace.
I N STA L L AT I O N M A N UA L 6.3 Assembly regulations with flammable materials (Figure 6.3 and 6.4) Load-bearing walls and ceilings must be covered in a protective fire resistant plate. Never use flammable materials around the fireplace or cove. The minimal distance between the device and non-flammable materials must be at 50 mm to ensure a convection air flow.
I N STA L L AT I O N M A N UA L 7 ATTENTION POINTS GAS FLUE 8 INSTALLATION CHECK AND FIRST USAGE 8.1 Renovation/new construction To guarantee the fire safety regarding you flue gas configuration a casing is necessary. For this case non-combustible materials should be used.
Every fireplace is provided with a main adapter. adjusted for Element4 devices. Up to eight devices can be used with one app, in the situation that multiple fire are installed in the same location.
Use cleaning supplies qualified by Element4. • When you clean your Anti-Reflective glass, make sure you use this with the special Element4 cleaner, which is available only via Element4. • Use only a microfibre cloth. Other materials such as kitchen towels, steel wool etcetera can cause scratches or damage the coating on the glass.
Page 13
I N STA L L AT I O N M A N UA L Figure 10.2 - Remove top trim screws Figure 10.3 - Remove top trim Figure 10.4 - Remove side trims Figure 10.5 - Remove bottom trim Figure 10.6 - Remove clamps Figure 10.7 - Remove glass cords Figure 10.8 - Put on suction cups Figure 10.9 - Remove glass...
I N STA L L AT I O N M A N UA L 11 DECORATION ARRANGEMENT Position the decoration logs as shown on the image below. Only the decoration ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown on this page. Make sure that the pilot flame area and the second Replacement parts are available from your dealer, but should thermocouple are always free of any decorative material to...
(sanding) sponges, abrasives and cleaning agents with ammonia is prohibited. Only use a neutral cleaning product 12.1 Hand over to the customer (neither acidic nor alkaline), such as Element4 window cleaner (Item No. 4500926). The cleaning agents that you normally use •...
A P P E N D I C E S A FIRST AID FOR MALFUNCTION Below you will find an overview of the possible cause and solution in the event of a failure. Problem Possible Cause Solution No transmission 1 Batteries in the receiver empty Replace the batteries (4x 1.5V AA) (motor will not 2 Batteries hand remote empty...
Page 17
A P P E N D I C E S 4,5 mV 4,5 mV Figure A-1: Bend pin Figure A-4: Testpoint A Figure A-5: interrupter Figure A-2: Antenna Figure A-6: Wiring receiver Figure A-7: Pilot set Figure A-3: Torx screw...
Page 18
A P P E N D I C E S Problem Possible Cause Solution The pilot light goes 1 Insufficient voltage across the thermocouple or Place the measuring pins of the multimeter on the ground and on but goes out too much resistance in the thermocouple circuit black cable of the breaker.
Page 19
A P P E N D I C E S Figure A.8: Second thermocouple Figure A.11: “Double plus”-button on the remote Figure A.9: Button A on “On” Figure A.13: SI-port Figure A.10: RESET-button Figure A.11: Aux-position receiver Figure A.14: Domotica system...
A P P E N D I C E S B ERRORS CODES PROCONTROL APP B.1 Messages shown in app Error Message in App Description Possible cause code Contact Service. • 5 sec. beep from Receiver • Microswitch not making contact with cam on motor knob •...
A P P E N D I C E S Error Message in App Description Possible cause code Contact Service. • Fire is not responding • Receiver or Wi-Fi Box malfunction • No electronic control of fire • Connection cable from Receiver to Wi-Fi Box defective Check Wi-Fi •...
A P P E N D I C E S C FAULTS AND ERROR CODES IN THE REMOTE This appendix can be consulted when error messages occur in the application for smartphone and tablet. C.1 F41 error This message will appear if there is no or bad Wi-Fi reception, this can be between app and router or Wi-Fi box and router By closing the App and opening it again, this is solved in most cases.
A P P E N D I C E S D LOCATION TERMINAL D.1 Terminal location with vertical exhaust (C11) D.2 Terminal location with Horizontal exhaust (C31) Distance Exhaust 1,2 of 3 Position terminal dist. (mm) At the same roof level >...
A P P E N D I C E S E GENERAL RULES FOR FLUE GAS EXTRACTION E.1 Power-Fan For flue configurations that do not function on natural draft, the PowerFan can be used. For extensive installation instructions and the operation of the PowerFan we refer to the manual of the PowerFan.
A P P E N D I C E S F CALCULATION TABLE FLUE GAS REDUCTION The calculation table shows when you need to place a flue gas ristrictor Result Action No ristrictor required √ Position the resitrictor No good operation guaranteed * F.1 Horizontal terminal flue diameter F.2 Vertical terminal flue diameter For a vertical terminal the minimal starting length is 0,5 meter...
A P P E N D I C E S G TECHNICAL DATA The dataplate specifies for which type of gas, gas pressure and for which country this appliance is intended. The nameplate is attached to a chain. It must remain attached to the chain. Note: Check whether the appliance is suitable for the gas type and gas pressure on site.
A P P E N D I C E S H ECODESIGN Since 1 January 2018 every fireplace has been provided with an eco-label which is always supplied with the fireplace. The ecolabel shows which category the fireplace belongs to. H.1 Ecolabels The ecolabels for the different types of gas are indicated below, respectively G20, G25 and G30.
A P P E N D I C E S I DIMENSIONAL DRAWINGS On this page and the following ones you will find dimensional drawings of the Sky Medium model and accessories with some of the important dimensions that you have to take into account when installing and installing your fireplace.
Page 29
A P P E N D I C E S 199,00 208,00 150,00 134,00 728,00(G) 46,00 732,00 (frame) 56,00 880,00 928,00 992,00 I.1 - Technical drawing of Sky Small T...
Page 32
E L E M E N T 4 B .V. Paxtonstraat 23 8013 RP Zwolle The Netherlands Info@element4.nl www.element4fires.com R E L E A S E DAT E | 1 0 / 0 4 / 2 0...
Need help?
Do you have a question about the Sky Small Series and is the answer not in the manual?
Questions and answers