Table of Contents

Advertisement

Quick Links

I N S TA L L AT I O N M A N U A L
I N S TA L L AT I O N M A N U A L
S K Y B S E R I E S - B I O E T H A N O L
Please leave these instructions behind with the device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKY B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Element4 SKY B Series

  • Page 1 I N S TA L L AT I O N M A N U A L I N S TA L L AT I O N M A N U A L S K Y B S E R I E S - B I O E T H A N O L Please leave these instructions behind with the device...
  • Page 2 I N S T A L L A T I O N M A N U A L D O N O T U S E T H I S P R O D U C T A S A P R I M A R Y H E A T S O U R C E A L W A Y S U S E B I O E T H A N O L O F 8 5 % T O 9 6 , 6 % A L C O H O L...
  • Page 3: Table Of Contents

    I N S T A L L A T I O N M A N U A L TABLE OF CONTENTS CE STATEMENT � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 IMPORTANT INFORMATION �...
  • Page 4 I N S T A L L A T I O N M A N U A L MAINTENANCE INSTRUCTION � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �18 10�1 MAINTENANCE IN THE COMBUSTION CHAMBER �...
  • Page 5: Ce Statement

    This declaration loses its validity when changes to the device are made • Wood without the written permission by Element4. You can ask for a copy of • Plastic the test certificates of all models via our general e-mail adress, which is •...
  • Page 6: Warranty

    In case the installer is not able to fix the problem himself, a request can be made to Element4 to do it for him, as long as the service can be done within the borders of the Benelux.
  • Page 7: Remote Control And Ignition

    Chapter 4 I N S T A L L A T I O N M A N U A L | REMOTE CONTROL AND IGNITION 4�1 REMOTE CONTROL 4�2 FILLING THE TANK Figure 4.1 The device is operated by remote image 4.1 control ( ) The remote control requires 4 penlite (type AAA) batteries.
  • Page 8: Turning The Fire Place Off

    Chapter 4 I N S T A L L A T I O N M A N U A L | 4�4 TURNING THE FIRE PLACE OFF The tank hose can be emptied by pressing the -FILL- button several times while holding the hose upright to prevent spillage. Make To turn off the fire, touch the ON button to activate the remote control sure the hose is completely free of fuel before disconnecting it.
  • Page 9: Installation Preparation And Instruction

    I N S T A L L A T I O N M A N U A L | Chapter 5 INSTALLATION PREPARATION AND INSTRUCTION The device has been developed, tested and approved to conform with applicable standards for the usage, performance and safety of the product.
  • Page 10: Installation Instructions

    I N S T A L L A T I O N M A N U A L | Chapter 6 INSTALLATION INSTRUCTIONS To install a fireplace as safely as possible, several installation preparations need to be made. This overview can be used to assure the fire safety of a conversion of a fireplace.
  • Page 11 I N S T A L L A T I O N M A N U A L | Chapter 6 Figure 6.3 | C11: Flue situation Non-Flammable materials Figure 6.5 | C11: Flue situation Flammable materials Figure 6.4 | C31: Flue situation Non-Flammable materials Figure 6.2 | C31: Flue situation Flammable materials...
  • Page 12: Other Rules Regarding Heat In Your Installation

    OUTDOOR INSTALLATION 6�4�2 CONVECTION This appliance is meant for indoor use. In the case that an Element4 The majority of the heat produced by Element4 fireplaces is quickly appliance is to be installed as part of an indoor outdoor construction, given off to the air around the fireplace.
  • Page 13: Attention Points Flue Gas Extraction

    Every transit or terminal should be made such, that the warmth- insulation and non-combustability is guaranteed, according to the building regulation. For help with the flue see the flue calcualtion page on the Element4 website: https://www.element4.nl/flue-calculation 7�1 DETERMINING THE FLUE GAS EXTRACTION DIAMETER The Sky series fireplaces have a flue diamter of 200/130.
  • Page 14: Calculate Flue Length

    I N S T A L L A T I O N M A N U A L | Chapter 7 Be aware of the bends in your flue. They provide extra resistance in the Not all parts can be adjusted! To fit the drainage system correctly, you system and must therefore be included in the TVS and THS.
  • Page 15: Safety

    I N S T A L L A T I O N M A N U A L | Chapter 8 SAFETY The Sky Bio-ethanol fireplace has several safety systems to ensure that it can be used in the safest way. Nevertheless, a few things must be taken into account: •...
  • Page 16: Maintenance Instruction Sky Rd

    Always clean the glass at room temperature. company or installer is prescribed. • Use a cleaning agent approved by Element4 for cleaning. • If you have anti-reflection glass in your fireplace, it must always be cleaned with the specially intended Element4 cleaning agent. This 9�1...
  • Page 17 I N S T A L L A T I O N M A N U A L | Chapter 9 Figure 9.3 | Remove top trim Figure 9.2 | Unscrew top trim Figure 9.5 | Remove bottom trim Figure 9.4 | Remove side trims...
  • Page 18 I N S T A L L A T I O N M A N U A L | Chapter 9 Figure 9.8 | Figure 9.6 | Place Suction cup on the glass Rotate glass clamps Figure 9.7 | Carefully lift the glas out of the fireplace...
  • Page 19: Maintenance Instruction

    Always clean the glass at room temperature. company or installer is prescribed. • Use a cleaning agent approved by Element4 for cleaning. • If you have anti-reflection glass in your fireplace, it must always be cleaned with the specially intended Element4 cleaning agent. This 10�1...
  • Page 20 I N S T A L L A T I O N M A N U A L | Chapter 10 Figure 10.2 | Figure 10.3 | Remove screws upper trim Remove upper trim Figure 10.5 | Remove bottom trim Figure 10.4 | Remove side trims...
  • Page 21 I N S T A L L A T I O N M A N U A L | Chapter 10 Figure 10.6 | Remove glass brackets Figure 10.7 | Remove glass rope Figure 10.8 | Place Suction cup on the glass Figure 10.9 | Carefully lift the glas out of the fireplace...
  • Page 22: Burner Maintenance

    11�2�3 THERMOCOUPLE The Element4 bioethanol fireplace has a thermocouple that checks whether a fire is burning. It is important that it is clean so that the flame properly heats up the thermocouple. Make sure there is no decorative material between the flame and thermocouple.
  • Page 23: Decorative (Ceramic) Parts

    Figure 12.1 | Logset Sky B series Lay the filament over the burner making sure it is within the orange box Figure 12.2 | Step 1 remains.
  • Page 24 I N S T A L L A T I O N M A N U A L | Chapter 12 Figure 12.3 | Step 2 Lay log 1 and 2 with the slit at the bottom over the upright edge. Make sure that the (circled) pins on the logs are on the correct side.
  • Page 25 I N S T A L L A T I O N M A N U A L | Chapter 12 Figure 12.5 | Step 4 Place the coals (5) in the designated places and then place the logs 6 and 7 Figure 12.6 | Step 5...
  • Page 26: Operating The Fireplace

    I N S T A L L A T I O N M A N U A L | Chapter 13 OPERATING THE FIREPLACE 13�1 BEFORE THE FIRST FIRE 13�3�2 SMELL CHECK When the fireplace is first heated, an odour may be given off by the hot Make certain that all construction materials have been removed metal.
  • Page 27: Atroubleshooter

    I N S T A L L A T I O N M A N U A L | Appendix A TROUBLESHOOTER A�A FIRST AID FOR MALFUNCTION Below you will find an overview of the possible cause and solution in the event of a failure.
  • Page 28: A�Bnecessary Tools

    If a problem is found, that cannot be solved on site, always contact your Element4 expects are being carried during said services. dealer or directly contact Element4 via our credentials which can be When all these tools are available during service, Element4 guarantees found on the back page of this manual.
  • Page 29: Berror Codes

    I N S T A L L A T I O N M A N U A L | Appendix B ERROR CODES B�A MESSAGES SHOWN IN REMOTE CONTROL The installed software will give an error/stop code if the bioethanol fire has stopped or not started for any reason.
  • Page 30 I N S T A L L A T I O N M A N U A L | Appendix B Foutcode Omschrijving Mogelijke redenen Mogelijke oplossing Time out, waiting • The fuel did not reach the high sensor in •...
  • Page 31: Cterminal Location

    I N S T A L L A T I O N M A N U A L | Appendix C TERMINAL LOCATION C�B TERMINAL LOCATION WITH HORIZONTAL EXHAUST (C31) C�A TERMINAL LOCATION WITH VERTICAL EXHAUST (C11) Distance Exhaust 1,2 of 3 Position terminal dist.
  • Page 32: Dcalculation Tables Fluegas Restriction

    Appendix D I N S T A L L A T I O N M A N U A L | CALCULATION TABLES FLUEGAS RESTRICTION The calculation table shows when you need to place a flue gas ristrictor This fireplace has no minimal starting length. the flue can start with a bend directly from the top of the fireplace.
  • Page 33: Etechnical Data

    I N S T A L L A T I O N M A N U A L | Appendix E TECHNICAL DATA The values below depend on the type of Bioethanol used and the way in which the fire is built in. Note: Always use Bio-Ethanol with 85% to 96.6% alcohol.
  • Page 34: Fecodesign

    I N S T A L L A T I O N M A N U A L | Appendix F ECODESIGN Since 1 January 2018 every fireplace has been provided with an eco- label which is always supplied with the fireplace. The ecolabel shows which category the fireplace belongs to.
  • Page 35: Gdimensional Drawings

    I N S T A L L A T I O N M A N U A L | Appendix G DIMENSIONAL DRAWINGS On this page you will find trhr dimensional drawings of the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace.
  • Page 36 I N S T A L L A T I O N M A N U A L | Appendix G SKY M RD 1013 Frame Fire view Fire view 753 ext. Frame Figure G.B | Technical drawing of Sky M RD...
  • Page 37 I N S T A L L A T I O N M A N U A L | Appendix G SKY L RD 1013 Frame Frame Fire view Fire view 753 ext. Frame Figure G.C | Technical drawing of Sky L RD...
  • Page 38: Hdimensional Drawings

    I N S T A L L A T I O N M A N U A L | Appendix H DIMENSIONAL DRAWINGS On this page you will find trhr dimensional drawings of the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace.
  • Page 39 I N S T A L L A T I O N M A N U A L | Appendix H 199,00 208,00 150,00 134,00 724,00(G) 732,00 (frame) 46,00 56,00 250,00 880,00 928,00 992,00 Figure H.B | Technical drawing of Sky L T...
  • Page 40 I N S T A L L A T I O N M A N U A L | Appendix H 199,00 192,00 131,00 724,00 256,00 650,00 728,00 732,00 928,00 992,00 Figure H.C | Technical drawing of Sky M F...
  • Page 41 I N S T A L L A T I O N M A N U A L | Appendix H 199,00 208,50 131,00 724,00 256,00 650,00 728,00 732,00 928,00 992,00 Figure H.D | Technical drawing of Sky M T...
  • Page 42 I N S T A L L A T I O N M A N U A L | Appendix H 199,00 192,00 150,00 134,00 728,00(G) 732,00 (frame) 42,00 46,00 56,00 880,00 928,00 992,00 Figure H.E | Technical drawing of Sky S F...
  • Page 43 I N S T A L L A T I O N M A N U A L | Appendix H 199,00 208,00 150,00 134,00 728,00(G) 46,00 732,00 (frame) 56,00 880,00 928,00 992,00 Figure H.F | Technical drawing of Sky S T...
  • Page 44 I N S T A L L A T I O N M A N U A L | Notes 4 3 4 3...
  • Page 45 Design & Assembly by: E L E M E N T 4 B . V. Info@element4.nl www.element4.nl 0 2 / 0 8 / 2 3 RELEASE DATE |...

Table of Contents