Ventilation Requirements
• The appliance should be installed in a room or space with an air supply in accordance with the latest edition of
BS5440-2.
• For rooms with a volume of less than 5m
• For rooms with a volume of between 5m
unless the room has a door which opens directly to the outside air in which case no permanent ventilation is
required.
• For rooms with a volume greater than 10m
• Regardless of room size, all rooms containing the appliance must have direct access to the outside air
via a window that opens or equivalent.
• Where there are other fuel burning appliances in the same room, the latest edition of BS 5440-2 should
be consulted to determine the correct amount of free area ventilation requirements.
Gas Installation
This cooker uses and is ready to use NATURAL GAS only and cannot be used with any other gas without
modification. This appliance is manufactured for conversion to LPG after fitting new injectors and making
adjustments. Refer to "replacement of burner injectors" section for details.
Installation and Service Regulations
This appliance must be installed and serviced only by a suitably qualified and Gas Safe Registered
engineer, and in accordance with the current editions of the following standards and regulations or other
locally applicable regulations:
• Gas Safety (Installation and Use) Regulations
• Building Regulations
• British Standards (BS 5440, BS 6172 and BS 6891)
• Regulations for Electrical Installation (BS 7671, (17
3
— permanent ventilation of 100cm
3
3
and 10m
a permanent ventilation of 50cm
3
— no permanent ventilation is required.
Edition))
th
2
free area will be required.
2
free area will be required
21