Table for the Choice of the Injectors
Large Burner (Fast)
Standard Burner
Small Burner (Simmer)
Grill Burner
Oven Burner
Lubrication of the Gas Taps
A Gas Safe Registered Engineer must lubricate the gas taps.
• All intervention regarding installation maintenance and conversion of the appliance must be fulfilled
with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Electrical Connection
• This cooker is fitted with a BS1363 moulded plug. The mains plug must remain accessible when the cooker is in
its place of use.
• If the installation requires any alterations to the domestic electric system, this must be performed by a qualified
electrician.
• The mains cable should be routed away from any hot parts.
• If the mains cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
• Ensure all terminal screws are adequately tightened. Do not over tighten as you may risk damaging the screw
threads.
26
Burner Injector Values
According to the Gas Type
Injector
Gas Flow
Power
Injector
Gas Flow
Power
Injector
Gas Flow
Power
Injector
Gas Flow
Power
Injector
Gas Flow
Power
LPG
G 30-30
mBar
mm
0.850
m3/h
0.083
gr/h
kW
3.000
mm
0.650
m3/h
0.047
gr/h
kW
1.780
mm
0.500
m3/h
0.026
gr/h
kW
0.880
mm
0.600
m3/h
0.041
gr/h
kW
1.500
mm
0.700
m3/h
0.063
gr/h
kW
2.160
Natural Gas
G 20-20
mBar
1.150
0.253
2.770
0.970
0.167
1.780
0.720
0.092
0.990
0.950
0.162
1.780
0.970
0.178
1.830
Need help?