Ventilation Requirements

• This appliance is not connected to a combustion products evacuation device. It should be installed and
connected in accordance with current installation regulations. Particular attention should be given to the
relevant requirements regarding ventilation.
• The appliance should be installed in a room or space with an air supply in accordance with the latest edition
of BS5440-2.
• For rooms with a volume of less than 5m
• For rooms with a volume of between 5m
unless the room has a door which opens directly to the outside air in which case no permanent ventilation
is required.
• For rooms with a volume greater than 10m
• Regardless of room size, all rooms containing the appliance must have direct access to the outside air
via a window that opens or equivalent.
• Where there are other fuel burning appliances in the same room, the latest edition of BS 5440-2 should
be consulted to determine the correct amount of free area ventilation requirements.

Gas Installation

This cooker uses and is ready to use NATURAL GAS only and cannot be used with any other gas without
modification. This appliance is manufactured for conversion to LPG after fitting new injectors, new supply
hose and making adjustments. Refer to "replacement of burner injectors" section for details.

Gas Installation Checks

After installation, check for gas soundness. The supply pressure can be checked at the front left hotplate
burner injector.

Installation and Service Regulations

This appliance must be installed and serviced only by a suitably qualified and Gas Safe Registered
engineer, and in accordance with the current editions of the following standards and regulations or other
locally applicable regulations:
• Gas Safety (Installation and Use) Regulations
• Building Regulations
• British Standards (BS 5440, BS 6172 and BS 6891)
• Regulations for Electrical Installation (BS 7671, (Latest Edition))
Currys Essentials Free Standing GAS Cooker CFSG60W17 Manual.indd 9
Currys Essentials Free Standing GAS Cooker CFSG60W17 Manual.indd 9
3
— permanent ventilation of 100cm
3
3
and 10m
a permanent ventilation of 50cm
3
— no permanent ventilation is required.
2
free area will be required.
2
free area will be required