Kingsman ZVFCV39 Owner's Operation And Installation Manual page 34

Table of Contents

Advertisement

CAUTION
Any safety screen or guard removed for servicing an
appliance must be replaced prior to operating the heater.
NOTICE
A qualified gas appliance installer must connect the
fireplace to the gas supply. Consult all local codes.
CAUTION
Use new black pipe only. Internally tinned copper
tubing can be used in some areas when permitted by
local codes. Only use pipe of 1/2" or greater diameter
to allow full gas volume to heater. Excessive pressure
loss will occur if the pipe is too small.
A manual shutoff valve, union and plugged
pressure tap pointer must be installed upstream of the
heater.
A sediment trap must be installed upstream of the heater
to prevent moisture and contaminants from passing
through the pipe to the heater controls and burners. Failure
to do so could prevent the heater from operating
reliably.
INSTALLING – Gas Line Cont.
1
" NPT
8
regulator. Check pressure at the pressure test point, which is
located on the side of the gas control near the pilot outlet.
Make sure that the pressure tap is completely closed after
checking gas pressure. The pressure should be checked with
the appliance burning and the control set on high.
IMPORTANT: Loosen the pipe adapter on the flex tube
before installing to the system piping.
CHECK GAS TYPE: The gas supply must be the same as
stated on the heater's rating plate. If the gas supply is
different, Do Not Install the heater. Contact your dealer for
the correct model.
CAUTION
All gas piping and connections must be tested for leaks
after installation is completed. To test, turn gas valve on,
then apply a soap and water solution to all connections
and joints. If bubbles appear, leak can be detected and
corrected. Never use an open flame for leak testing.
Never operate any appliance if a leak is detected!
For the state of Massachusetts a T-handle gas shut-off
valve must be used on a gas appliance. This T-handle gas
shut-off valve must be listed and approved by the state of
Massachusetts. This is in reference to the state of
Massachusetts state code CMR238.