Remove the DIMM.
7.
To replace the component, reverse the removal procedure.
Heatsink
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
WARNING: A warning contains information essential to physical safety. The text should point
out physical hazards, calling attention to procedures and practices that must be followed to
prevent serious injury or death.
To remove the component:
Power down the server (on page 30).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 30).
o
Remove the server from the rack (on page 33).
o
Remove the access panel
4.
Remove the air baffle (on page 34).
5.
Remove the heatsink:
6.
Loosen one pair of diagonally opposite screws halfway, and then loosen the other pair of screws.
a.
Completely loosen all screws in the same sequence.
b.
("Access
panel" on page 40).
Removal and replacement procedures 55