Summary of A/V Notifications
SOUND
CAUSE
LOUD,
FIRE ALARM or CO ALARM
INTERRUPTED*
(CO: keypad/detector only; not
Keypad & Ext.
external sounder)
LOUD,
BURGLARY/AUDIBLE
CONTINUOUS*
EMERGENCY ALARM.
Keypad & Ext.
ONE SHORT
a. SYSTEM DISARM.
BEEP
b. SYSTEM ARMING ATTEMPT
(not repeated)
WITH AN OPEN ZONE.
Keypad only
c. BYPASS VERIFY.
ONE SHORT
a. SYSTEM IS IN TEST MODE.
BEEP
b, LOW BATTERY AT A
(about every 30
TRANSMITTER.
seconds)
c. SYSTEM WILL AUTOARM
Keypad only
WITHIN 10 MINUTES
TWO SHORT
ARM AWAY or MAXIMUM.
BEEPS
Keypad only
THREE SHORT
a. ARM STAY, NIGHT-STAY,
BEEPS
OR INSTANT.
Keypad only
b. ZONE OPENED WHILE
SYSTEM IS DISARMED.
RAPID
a. TROUBLE.
BEEPING
b. MEMORY OF ALARM.
Keypad only
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL.
e. LAST 10 SEC of EXIT DELAY
SLOW
a. EXIT DELAY WARNING (if
BEEPING
programmed).
Keypad only
b. ENTRY DELAY WARNING.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 52 –

Alpha Display Keypads

National Security Systems (800) 457-1999
(cont'd)
DISPLAY
FIRE or ALARM (for CO) is displayed;
descriptor of zone in alarm is displayed. If a fire
alarm is manually activated, zone number 95
will be displayed.
ALARM is displayed. If programmed,
descriptor of zone in alarm is also displayed
a. DISARMED/READY TO ARM is displayed.
b. Number and descriptor of open protection
zone is displayed.
c. Numbers and descriptors of the bypassed
zones are displayed (One beep occurs for each
zone displayed). Then, the following displays:
DISARMED BYPASS /Ready to Arm.
a. Opened Zone identifications will appear.
b. LO BAT displayed with description of
transmitter.
c. No special display.
ARMED AWAY or MAXIMUM displayed. Red
ARMED indicator lit.
a. ARMED STAY or ARMED INSTANT
displayed. Red ARMED indicator lit.
b. CHIME displayed, descriptor of open
protection zone will be displayed if the
[✱] key is pressed.
a. CHECK displayed. Descriptor of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of
zone in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
e. No special display.
a. ARMED AWAY or MAXIMUM is displayed
along with You May Exit Now.
b. DISARM SYSTEM OR ALARM WILL
OCCUR is displayed. Exceeding the delay
time without disarming causes an alarm.