Summary Of Audible/Visual Notifications - Honeywell VISTA-20P User Manual

Ademco vista series
Hide thumbs Also See for VISTA-20P:
Table of Contents

Advertisement

Summary of Audible/Visual Notifications

Fixed-Word Display Keypads
SOUND
CAUSE
LOUD,
FIRE ALARM or CO ALARM (CO:
INTERRUPTED *
keypad/detector only; not external
sounder)
Keypad & Ext.
LOUD,
BURGLARY/AUDIBLE
CONTINUOUS *
EMERGENCY ALARM
Keypad & Ext.
ONE SHORT
a. SYSTEM DISARM
BEEP
b. SYSTEM ARMING ATTEMPT
(not repeated)
WITH AN OPEN ZONE.
Keypad only
c. BYPASS VERIFY
ONE SHORT
a. SYSTEM IS IN TEST MODE
BEEP
b. LOW BATTERY AT A
(about every 30
TRANSMITTER
secs)
c. SYSTEM WILL AUTOARM
Keypad only
WITHIN 10 MINUTES
TWO SHORT
ARM AWAY or MAXIMUM
BEEPS
Keypad only
THREE SHORT
a. ARM STAY, NIGHT-STAY,
BEEPS
INSTANT
Keypad only
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE.
RAPID
a. TROUBLE
BEEPING
b. MEMORY OF ALARM
Keypad only
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
e. LAST 10 SEC of EXIT DELAY
SLOW
a. EXIT DELAY WARNING
BEEPING
b. ENTRY DELAY WARNING
Keypad only
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
National Security Systems (800) 457-1999
DISPLAY
FIRE or ALARM (for CO) is displayed; zone
number of zone in alarm is displayed. If a fire
alarm is manually activated, zone number 95
will be displayed.
ALARM is displayed. Zone number of zone
in alarm is also displayed.
a. READY indicator light comes on.
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
c. No special display.
AWAY is displayed. Red ARMED indicator is
lit.
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the [✱]
key is pressed.
a. CHECK displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone
number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70 is displayed.
e. No special display.
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.