2.5.13 Technical data

Model
GENERAL
RPM
Alternator
Engine: Mitsubishi diesel, model
Number of cylinders
Displacement
Bore X stroke
Combustion air consumption
Continuous power engine
Cooling system
Cooling water pump
Fuel lift pump engine
Starting battery (optional)
Fuel consumption
Control
ELECTRICAL SPECIFICATIONS
Output voltage
Output rating at powerfactor cos phi = 1
Voltage tolerance
Frequency tolerance
Alternator
Voltage regulation:
MECHANICAL SPECIFICATIONS
Supply includes
Dimensions hxwxd
Colour
Weight (including canopy)
Max. installation angle
Standard supplies
Optional mobile
* Electronic governor
EN / M-SC6/8/10 / December 2010
account calculating the right mixture. The cooling liquid in
the engine is pressurised and has a boiling point above
100° C. The temperature switch in the thermostat housing
switches at 110° C. When keel cooling or radiator cooling
is applied the cooling system is not pressurised. There
should be a special cap on the manifold without valves
leaving the connection to the expansion tank open. Refer
to the manual on keel cooling and radiator cooling.
M-SC6
3000
water cooled, synchronous
L2E
2
635 cm3
76x70 mm
0.9 m3/min
5 kW
indirect cooling by raw water, 10-15 l/min.
PTO driven WhisperPower self priming impeller pump, type M
electric pump (12 V DC), additional pump available upon request
60-90 Ah 12V
1.5-4 litre/hour, load dependent
Digital Diesel Control including automatic start/stop
230V 50 Hz alternating current (AC) single phase
5 kW
± 5%
± 5%
brushless, two pole, synchronous
capacitor
generating set, built into tugged GRP sound shield with steel base plate, mounted
on rubber anti vibration mounts
660x495x550 mm
top white, bottom green
178 kg
25 degrees
remote panel (+15 m cable), fuel lift pump, expansion tank
Installation kits, mobile (vehicle) version, non-earth return, spare part kits
M-SC8
3000
L2E
2
635 cm3
76x70 mm
0.9 m3/min
6,4 kW
6,4 kW
± 5%
± 1% *
capacitor + AVR (option)
660x495x550 mm
182 kg;
25 degrees
INFORMATION
M-SC10
3000
L3E
3
952 cm3
76x70 mm
1,4 m3/min
10,5 kW
9.4 kW
± 5%
± 1% *
capacitor + AVR (option)
810x525x615 mm
210 kg
25 degrees
15