INSTALLATION
One can mount the control panel after drilling a hole in the
dashboard using the plastic cover. Refer to the
dimensional drawing in paragraph 3.5. The panel without
the plastic cover fits the Mastervision modular panel
system.
More remote control panels (slave panels) can be put in
parallel by using the modular connectors on the back of
the units. As a slave one can use the same panel offering
all functions again. It is also possible to use an old or new
type slave panel only to start and stop the generator.
Old type remote panels and system panels can be
connected by means of the green connector.
Pay attention to the colour codes as indicated in fig. 17
when fitting cable to the green connector. Some software
versions in old system panels (supplied before May 2004)
could conflict with the software in the DDC and an update
of the software of the system panel could be necessary.
When this is the case consult to the Whisper Power
service department for advice.
When using the factory settings, installation is very simple:
just plug the remote cable into the remote and the
generator is ready to use. Refer to fig. 17.
Whisper Remote Panel
Fig. 17 Remote box terminals
14
REMOTE CABLE
REMOTE CABLE
WIRING COLOURS
1
RED
2
GREEN
3
BROWN
4
YELLOW
5
PINK
6
PURPLE
7
BLUE
8
WHITE
9
RED/BLUE
10
GREY/PINK
11
GREY
12
BLACK
SENSE BAT. 2
WARNING RELAY
MAX. 150 mA
Acoustic alarm or warning lamp
One can connect an external max.150 mA relay to
generate an acoustic warning or applying a warning lamp
etc. Be aware of polarity as some relays has a diode
inside and should be connected plus to plus en minus to
minus as indicated. Refer to fig. 17.
Connection for emergency stop / fire alarm switch
To connect an emergency stop button or to stop the
generator automatically in case of a fire alarm, you can
use the bypass connection between fastons J7 and J18 on
the backside of the local control panel. See fig. 18. To do
so, remove this bypass connection and then replace it by
an emergency switch or a potential free fire alarm switch
with normally closed contacts
Normal operation
Alarm / emergency
Fig. 18: Connection for emergency stop / fire alarm switch
Automatic start/stop
Whisper Power cannot be held responsible
for damage caused by the unattended
running
generator
start/stop mode or interval mode
Using the auto-start/stop (interval) mode
the generator can start unexpectedly.
When working on the electrical system, the
3 Amp fuse must be removed from the
control panel and the battery plus cable
must be removed from the battery.
The Whisper Power Digital Diesel Control system offers
several options for automatic starting and stopping.
Access to this menu and other menus could be blocked.
For blocking and setting up this options refer to the
APPENDIX of the DDC users manual.
December 2010 / M-SC 6/8/10 - 3000RPM / EN