4. mANuAL mETAL ARC wELdING

The FastMig™ power source can be used in electrode welding by connecting a FastMig™
MSF 53, MSF 55 wire feeder to it. The power source can be made suitable for electrode welding
without a wire feeder by connecting an R10 or R20 remote control to the X14 or X15 terminal at the
back of the power source for welding current adjustment, and the welding power cable connected
to the power source's (+) connector X11 or X12.

5. mAINTENANCE

The amount of use and the working environment should be taken into consideration when planning
the frequency of maintenance of the machine. Careful use and preventive maintenance will help
to ensure trouble-free operation.

5.1. CAbLES

Check the condition of welding and connection cables daily. Do not use damaged cables.
Make sure that the mains cables in use are safe and according to laid down regulations.
The repair and mounting of a mains connection cable should be carried out only by an authorised
electrician.

5.2. POwER SOuRCE

Note! Disconnect the plug of the machine from the mains socket and wait approx.
2 minutes (capacitor charge) before removing the cover plate.
Check at least every half year:
– Electric connectors of the machine - clean the oxidised parts and tighten the loosened
ones.
– Note! You must know correction tension torques before starting the reparation of the
joints.
– Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and vacuum
cleaner. Also clean the ventilation net behind the front grate.
– Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps of
cooling profiles.
– Do not use pressure washing device.
– Only authorised electrician shall carry out repairs to the machines.

5.3. REGuLAR mAINTENANCE

Kemppi Service Workshops make regular maintenance according to agreement.
The major points in the maintenance procedure are listed as follows:
– Cleaning of the machine
– Checking and maintenance of the welding tools
– Checking of connectors, switches and potentiometers
– Checking of electric connections
– Checking of mains cable and plug
– Damaged parts or parts in bad connection are replaced by new ones
– Maintenance testing. Operation and performance values of the machine are checked, and
adjusted when necessary by means of test equipment.
 – Fastmig™ Kms 400 mVU / 0647