GENERAL XE/YE-CLASS TOPSIDE
An Internal hardware error has been detected in in.xe.
Water temperature at the heater has reached 119˚F.
Temperature inside the spa skirt is too high, causing the internal
temperature in the in.xe to increase above normal limits.
The system did not detect any water flow while the main pump
was running.
The Prr error message indicates a problem with regulation probe.
The system is constantly verifying if temperature probe reading
is within normal limits.
Water temperature in the spa has reached 108˚F.
Sec1:54

DIAGNOSTIC MESSAGE

• Restart the spa pack and start and stop all
pumps and blower.
• If error reappears, replace in.xe spa pack.
DO NOT ENTER SPA WATER!!!
• Restart the spa pack.
• If error persists, measure the temperature with a digital
thermometer and compare. Its reading with temp. on the
display. Make sure the temp. reading is lower than 119˚F.
• If problem persists, replace pack.
• Remove spa skirt and let system cool down, until the
error clears.
• Make sure valves are open and that water level is
high enough.
• Check and remove anything obstructing the filter.
• Make sure there are no air locks or that no object
obstructs the passage of the water in the heater channel.
Pumps may make strange noises. Follow air lock
procedure to clear them.
• Verify if regulation probe located above the heater is
properly connected.
• Replace in.xe heater is problem persists.
DO NOT ENTER SPA WATER!!!
• Measure the temperature with a digital thermometer
and compare its reading with temp on the display. If temp
reading is different, replace heater.
• Remove spa cover and let spa cool down.
• Add cold water and lower filter cycles.
• If problem persists replace pack.