SPA (XE / YE-CLASS) WIRING DIAGRAM
The Diagram intended for the XE / YE-Class Pack System
Wiring Requirements
• 2-Hots, 1-Neutral, 1-Isolated Ground
• 4 Wire #6 AWG minimum 75˚C copper conductor
Factory Recommended G.F.C.I. Load Center Wiring
Note: The white neutral wire from the back of the GFCI MUST be connected
to an incoming line neutral. The internal mechanism of the GFCI requires this
neutral connection. The GFCI will not work without it.
Note: Connection order may vary by pack model, please refer to
equipment pack panel for proper connection order.
Sec1:25
Wiring Requirements:
White Pigtail
White Pigtail
WHITE WIRE
(White Wire
(White Wire
TO THE SPA
To the Spa)
To the Spa)
TO SPA
To:
Spa
To:
NOTE!
Spa Operator's Guide
Neutral Bar
For spa wiring
configuration please
Spa
refer to page 22 or
equipment pack for
detailed information
Neutral Bar