Heatline solaris 24PC Installation, Servicing & User Instructions page 45

Pre-mix condensing combination boiler
Table of Contents

Advertisement

Supplied by HeatingSpares247.com
The operational time periods may be set as
follows:
Rotate the clock actuator mechanisms
clockwise, by hand, until the small black
triangle indicates the current time, see
figure 5. In figure 5, current time is 21:05.
The timer uses 24 hour format, e.g. the
time for 1pm the time is 13:00 hrs.
Select the "On" times by pushing the black
tappets to the outside.
Select the 'Off' times by pushing the black
44
tappets towards the centre of the clock.
E.g. The clock shown in diagram 2 is set as
follows:
The clock operation can be set by a selection
switch.
The switch has 3 positions:
1 (Up) position: The boiler is controlled by the
function switch (Item 1 in Figure 3) and
allows continuous operation.
(Mid) position: The boiler heating circuit is
controlled by both function switch and clock
tappets, whilst hot water is delivered on
demand.
0 (Down) position: The boiler is off,
independent of the function switch.
FROST PROTECTION
The boiler has a built in frost protection device
that protects the boiler from freezing. If the
boiler is to be left and there is a risk of frost,
ensure that the gas and electrical supplies are
left connected. The frost protection device will
light the boiler when the temperature of the
boiler water falls below 6
Figure 5
o
C. When the
Page 45
o
temperature reaches 15
down.
Note: This device works irrespective of any room
thermostat setting and will protect the boiler, but
not necessarily the full system.
vulnerable sections of the circuit are adequately
lagged.
ANTI PUMP SEIZURE
Note
the
pump
will
automatically in order to avoid seizure. See Daren
for time specification
SYSTEM PRESSURE.
On installation your installer will have filled the
boiler and system to its effective working
pressure. The boiler's pressure sensor should be
regularly checked on the LCD to ensure that this
pressure is maintained between 1 and 2 bar. If
there is a significant loss in pressure the boiler
will lock out. The system may be re-charged by
opening the filling loop to charge the system back
up to 1.5bar as indicated on the LCD panel. DO
NOT
OVERCHARGE
PRESSURE BEYOND 2BAR AS THE BOILER
WILL NOT OPERATE.
flexible hose with two valves, should be located
below the boiler connecting the second pipe from
the right to either one of the outer pipes, see
figure 10 on page 19. DO NOT CLOSE ANY
OF
THE
FOUR
CONNECTING TO THE BOILER. If the boiler
frequently loses pressure then your installer
should be consulted.
solaris 24PC, 30PC
C, the boiler will shut
Ensure that
occasionally
operate
THE
BOILER
The filling loop, a
VALVES