Figure 3
TERMINAL POSITION
A-
Directly below an openable window or other opening e.g. air brick
B-
Below gutters, soil pipes or drain pipes
C-
Below eaves
D-
Below balconies or car front roofs
E-
From vertical drain pipes and soil pipes
13
F-
From internal or external corners
G-
Above ground, roof or balcony level
H-
From a surface facing a terminal
I-
From a terminal discharging towards another terminal
J-
From an opening in a car port (e.g. door, window) into a dwelling
K-
Vertically from a terminal on the same wall
L-
Horizontally from a terminal on the same wall
M- Above an opening, air brick, opening windows, etc.
N-
Horizontally to an opening, air brick, opening windows, etc.
P-
Above roof level (to base of terminal)
Q-
From adjacent wall to flue
R-
From an adjacent opening window
S-
From another roof terminal
Internal Corner
External Corner
Page 13
solaris 24PC, 30PC
MINIMUM
DISTANCE
300 mm
75 mm
200 mm
200 mm
150 mm
300 mm
300 mm
600 mm
1200 mm
1200 mm
1500 mm
300 mm
300 mm
300 mm
300 mm
300 mm
1000 mm
600 mm
Double Corners