8. Flue (General)

8.1 The boiler utilises a concentric flue
arrangement which consists of a 60mm-
diameter inner flue and 100mm-diameter outer
air inlet duct.
8.2. A standard 700+/-5mm flue kit (figure 4)
is supplied with the boiler, which can be
routed to the rear, left or right of the appliance
by means of a 90
bend is connected to the boiler using the
screws provided and sealed with the gasket.
14
8.3. The horizontal 60/100cm flue pipes may
be extended up to a maximum of 7m using
additional spare components available from
your supplier.
8.4. A vertical 60/100cm flue kit is also
available (figures 6a & 6b) from your supplier
up to a maximum length of 8m. The terminal
is suitable for a flat or pitched roof.
8.6. The connection of the vertical flue system
is similar to the Horizontal flue connection.
However, the 80/125 system is connected with
screws to the boiler and the vertical extension
pipes and roof terminal are connected by clips
as shown in figure 6b, item 3.
0
degree bend (figure 5). The
Figure 4
Figure 5
Note. For each additional 90º elbow used the
maximum flue length must be reduced by 1.5
m, whilst the use of 2 x 45º bends warrants a
reduction of 2m.
ONLY A HEATLINE APPROVED FLUE IS
TO BE USED WITH THIS PRODUCT.
FAILURE TO COMPLY WITH THIS
REQUIREMENT
YOUR GUARANTEE AND MAY LEAD TO
A DANGEROUS SITUATION.
Page 14
solaris 24PC, 30PC
WARNING!
WILL
INVALIDATE
Figure 6a