17.6 Release the hermetic chamber cover by
removing the two screws (figure 24) and then
lifting the cover to release it from the retaining
hooks at the top of the boiler.
25
Release the side panels by removing the
screws on the upper and lower sides
(figure 25). Remove the panels by
swinging them out and lifting them up.
Figure 23
17.7 Disconnect the electrical leads and gas valve
pipe connection from the fan (disconnect at the
gas valve taking care not to damage the restrictor),
remove the fan securing screws.
Figure 24
17.8 Remove the burner assembly from the
combustion chamber as follows:
Disconnect and remove the gas supply pipe
between the gas valve and fan, taking care not
to damage the restrictor in the top of the gas
valve.
Pull off the ignition and flame electrode leads
from the PCB and ignition transformer, and
remove the wires through the grommet on the
lower combustion chamber.
Remove the burner-retaining nuts and extract
the burner (figure 30).