Heatline solaris 24PC Installation, Servicing & User Instructions page 43

Pre-mix condensing combination boiler
Table of Contents

Advertisement

Supplied by HeatingSpares247.com
IMPORTANT INFORMATION.
The Heat Line™ boiler is a high efficiency gas
fired boiler and represents the highest level of
technology found in today's gas boiler market.
In order to maintain peak efficiency along with
optimum performance and reliability it is
essential that the boiler be serviced at least
once per year by a competent person such as a
CORGI Registered Engineer.
All C.O.R.G.I. Registered Installers carry a
C.O.R.G.I. ID card and have a registration
number, which should be recorded and entered
on your benchmark log book. You can check
your Installer registration by contacting
C.O.R.G.I. on 01256 372300
The boiler's 'Log Book' must be completed at
each Service visit.
GAS SAFETY (INSTALLATION AND
USE) REGULATIONS
42
It is a legal requirement that all gas appliances
must be installed and serviced by a competent
or C.O.R.G.I. registered person in accordance
with the above regulations. Failure to install or
service
invalidate your guarantee and could lead to
prosecution. It is in your interest and that of
safety to ensure compliance with the law.
For electrical safety the boiler must be earthed
and protected by a 5 -amp fuse.
Note. In the event of a fault the appliance
should not be used until a competent person
has corrected the fault.
VENTILATION
For maintenance and safety purposes, the
boiler has been installed with a minimum
space of 200mm above, 300mm below,
600mm to the front and 20mm to either side of
the boiler case. It is essential that this space is
not restricted by the addition of shelves etc.
fitted above or below the boiler, or to the
gas
appliances
correctly
boiler sides. See section 6 for detail. Do not store
flammable material or liquids near the boiler.
200
300
GENERAL DESCRIPTION OF THE
BOILER
The boiler is a combined domestic hot water and
central heating appliance. Its internal control unit
electronically provides direct burner ignition and
combustion supervision along with continuous
modulation of the burner's gas supply.
may
By means of a manual switch the boiler can be set
to operate in one of two operating modes,
domestic hot water only or domestic hot water and
central heating.
DOMESTIC HOT WATER MODE:
When hot water demand is requested, by the
opening of a hot water faucet, the boiler will fire
automatically. An integral pump is then energised
and hot water from the boilers primary circuit is
circulated through the secondary heat exchanger,
allowing the instantaneous transferral of heat to
the incoming cold water. The secondary heat
exchanger is protected against an internal build up
of lime scale by limiting the hot water
temperature at the tap to a maximum of 64°C. Hot
water will continue to flow through the tap until
no longer required. When the demand for hot
water ceases the integral pump may continue to
run for a short while to dissipate any excess heat
Page 42
solaris 24PC, 30PC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solaris 30pc

Table of Contents