Supplied by HeatingSpares247.com
Disconnect DHW sensor as described in
18.4.
Remove the screw securing the remaining
section of the diverter valve to the
combination boiler (figure 50).
33
Fit the replacement diverter valve and flow
sensor housing (figure 51) in reverse order
of removal ensuring all components are
assembled correctly.
Open the isolating valves on the flow and
return connections, refill, vent and
pressurise boiler ensuring all joints are
sound.
Figure 49
Figure 50
Figure 51
18.18 Filter
Drain the boiler's hydraulic circuit as detailed
in 18.2.
Remove the flow sensor housing as described
in 18.8.
Remove the filter on the inlet of the housing.
Clean or fit replacement filter.
Assemble the components in reverse order of
removal ensuring all components are
assembled correctly.
Open the isolating valves on the flow and
return connections, refill, vent and pressurise
the boiler ensuring all joints are sound.
18.19 Flow sensor
Remove the flow sensor by using a pair of
snipe nose pliers (figure 52).
Fit the replacement sensor in reverse order to
removal, using the cable connector if required.