NOTE:
When installing, commissioning or servicing
a gas appliance that incorporates a pre-mix
burner and zero-set governor, because it is not
possible to measure an operating pressure the
engineer should first check that the gas supply
is metered and ascertain whether it is possible
to measure the gas rate. If the gas input rate
can be measured then the requirements of
GSIUR 26(9) can be met, including any
specific
requirements
in
manufacturers'
instructions.If gas input rate cannot be
measured then, to satisfy the intent of GSIUR
26(9), the engineer shall measure the
combustion quality of the appliance in
accordance with BS 7967 or the technical
data of this manual.
If the engineer does not have the required
equipment and no alternative test is specified
by the manufacturer then the appliance shall
be turned off and disconnected as an un-
commissioned appliance until such time that
equipment is available to undertake such
tests.