6-4 Remove the camera from the tester, open the valve, and push in the cylinder knob lastly.
7. In case the inspected air-leaking time is out of standard
● If the air-leaking time is less than 6 seconds, the following defects should be considered.
① When the camera was assembled, there were defects in O-ring caused by being pinched, twisted, etc.
② There were dirt/dust or defects of the air-leak-tester attachment (with pad)/cradle cover.
③ There were defective connection between the tester and tube.
④ SD card/battery cover was not closed completely, or there were defective parts.
● Measure
① It is desirable to disassemble the whole again and reassemble it. (Confirm that O-ring is tightened by a
proper torque. Once O-ring is used, it cannot be reused because it affects drip-proof performance.
ref. Page A11 and A13 for details.)
② Clean up dust/dirt, or replace the attachment (with pad)/cradle cover.
③ Check the connection between the tester and tube.
④ Check that SD card/battery cover is surely closed or replace the parts.
valve
- A23 ・ S2 -
VAA36001-R.3667.A