5-2 After placing the attachment, fix them with rubber band, etc.   
  Note)
   ● Confirm there is NO misalignment between the multi-connector terminal and cradle cover.
   ● Confirm that the SD card/battery cover is surely closed.  
6. Air leak test
6-1 Pull the cylinder knob of the
tester, and reduce the pressure to
approx. " 15kPa(15 kilopascal) " .
  Note)
● Pull the cylinder knob at a
constant speed, with the valve
being OPEN.
● Do NEVER let the tester's hand
indicator go beyond 20kPa.
6-2 Close the valve immediately.
● Do not pull/push the cylyinder
knob, with the valve being
CLOSE.
6-3 When the tester's indicator to
"10kPa", start the measurement.
Make several measurements of the
leaking time, which is taken until
pointing to "0" position. Then,
calculate the average time of them.
 
  Standard: 6 or more sec. on average
SD card/Battery cover
Fix with rubber band.
Valve: Open
- A22 ・ S2 -
Attention:
Misalignment causes air
leakage, resulting in a
failure of measurement.
Cylinder knob
CLOSE
OPEN
VAA36001-R.3667.A
15kPa
CLOSE
OPEN