Section 3: Venting; Section 3-1: Converting To Rear Vent - Montigo PL38DF Installation & Maintenance Manual

Pl series
Table of Contents

Advertisement

PL38DF* Indoor Gas Fireplace

Section 3: Venting

Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is
the highest point in the venting assembly. It should also be selected
such that it provides the shortest vent run possible. Should it be
impossible to ensure that the termination is the highest point or
to meet the venting guidelines laid out below please contact your
Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or
through the rear
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer
to the appropriate section below for installation details
All fireplaces shipped from the factory are Top vent.
Silicone application is NOT required when joining Montigo
vent pipes and components.

Section 3-1: Converting to Rear Vent

Use the following instructions to convert an PL38DF* for Rear
Vent use:
1. Remove the Rear flue cover and gasket (5" and 8") on the
flue outlet, as shown in Figure 8.
2. Next, Remove the Top flue collar's (5" and 8") on the flue
outlet, as shown in Figure 8.
3. Install the (removed) Rear flue cover and gasket material, to
the Top vent outlet. Fasten the cover with included hardware,
as illustrated Figure 8a.
4. Install the (5" and 8") collars to the rear vent outlet using the
included hardware, as illustrated Figure 8a.
Flue Gasket
Flue Cover Plate
Figure 8. Flue cover and collar removal, Top Vented
fireplace.
Page 10
Installation
8" Outer Flue Collar
5" Inner Flue Collar
Figure 8a. Flue cover and collar installation, Rear Vented
fireplace.
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
5" Inner Flue Collar
8" Outer Flue Collar
Flue Cover Plate
Flue Gasket
XG0216 - 160215.1