WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
WARNING
Do not store or use gasoline or any other flammable vapours or
liquids in the vicinity of this or any other gas burning appliance. A fire
or explosion may occur resulting in serious injury, property damage
or death
Installation & Maintenance Manual
PVHEX58-300 & PVHEX510-300
5/8 and 5/10 External Wall
Power Vent
• The installation of this fireplace must be done by a
®
• Check local codes and read all instructions prior to
C
US
qualified and certified gas appliance installer.
installation.
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
Installation and service must be performed by a qualified installer,
service agency or the gas fitter.
NOTICE
This power vent is approved for use with Montigo fireplaces only and
is certified to ANSI Z21.50 / CSA 2.22 vented gas fireplace standard
along with the fireplace
WARNING
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
XG0517

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVHEX58-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo PVHEX58-300

  • Page 1 Follow the gas supplier’s instructions. NOTICE • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified This power vent is approved for use with Montigo fireplaces only and installer, service agency or the gas fitter. is certified to ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace WARNING...
  • Page 2: Safety Alert Key

    EPVH70 - 70 foot power cord and harness EPVH80 - 80 foot power cord and harness Specifications EPVH90 - 90 foot power cord and harness EPVH100 -100 foot power cord and harness Connect to fireplace PVHEX58-300 5"/8" 2700 RPM control Connect to fireplace PVHEX510-300 5"/10"...
  • Page 3: Table Of Contents

    General Contents Safety Alert Key .................. 2 General Information ................2 Specifications ..................2 Product Dimensions ................4 Unit Dimensions .....................4 Installation Locations ................ 5 Install ....................6 Installing the Power vent ................6 Installing the Power vent ................6 Wiring Diagram ....................8 Wiring Installation ...................8 Capacitor Replacement .................8 Motor and Capacitor Replacement ............10...
  • Page 4: Product Dimensions

    " 13" 13" " " " " 13" " PVHEX58-300 Side View 5" 8" " Power Head Framing Kit Rear View PVHEX10-300 " 10" Electrical Box Vent Retainer Figure 1. PVHEX58-300 & PVHEX510-300 (Tolerance ± ⅛") [mm] " Framing XG0517...
  • Page 5: Installation Locations

    Installation Installation Locations PVHEX58 300 V VENTER TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations US Installations Canadian Installations US Installations A= Clearance above grade, veranda, 12 in (30 cm) 12 in (30 cm) J= Clearance to nonmechanical air 6in (15 cm) for appliances <...
  • Page 6: Install

    Installation Install Installing the Power vent 2. Remove Power head from rough in box. " Framing Figure 2.d 3. Screw rough in box to wall. " Wall board Rough in box Figure 2. Framing dimensions (combustible material construction) Figure 2.e Installing the Power vent 4. Remove six screws securing the electrical cover. Remove cover 1.
  • Page 7 Installation 6. Take the electrical harness (EPVH-10-100) that will 10. Pass the vent pipe through the rough in box so it extends 6 communicate with the Power vent and pass the cable through 1/2 inches into the rough in box. the slot in the rough box.
  • Page 8: Wiring Diagram

    Operation Wiring Diagram Capacitor Replacement 1. Turn off power and gas. Figure 3.a 2. Remove 8 screws securing the outer cover of the power head. 8 fasteners (4 oposite side) Outer Cover Figure 3.b 3. Cut 3 zap straps securing wiring. Wiring Installation Figure 3.c Conduit &...
  • Page 9 Operation 9. Using the small bell connector, connect the brown wire from 5. Cut white wire from power cable, black wire from motor, and the motor to the black wire from the capacitor. black wire from capacitor. Figure 3.h Figure 3.e 10.
  • Page 10: Motor And Capacitor Replacement

    Operation Motor and Capacitor Replacement 5. Cut white wire from power cable, black wire from motor, and black wire from capacitor. 1. Turn off power and gas. Figure 4.e Figure 4.a 2. Remove 8 screws securing the outer cover of the power head. 6.
  • Page 11 Operation 9. Secure motor plate with supplied eight screws. Using the other supplied small bell connector, connect the brown wire from the motor to the black wire from the capacitor. Figure 4.i Figure 4.m 10. Attach new capacitor and the ground wire to the ground on the motor.
  • Page 12: Appendix B: Warranty

    (collectively referred to herein as "The Companies"), warrants the option, replace or repair defective components of the appliance Montigo gas appliance (referred to herein as 'the appliance') to manufactured by the company at no charge and will also pay for...
  • Page 13 In the event the installing dealer is unavailable, contact your nearest authorized Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance.
  • Page 14 Appendix Appendix C: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION. The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes...
  • Page 15 Notes XG0517...
  • Page 16 Installation & Maintenance Manual PVHEX58-300 & PVHEX510-300 5/8 and 5/10 External Wall Power Vent XG0517...

This manual is also suitable for:

Pvhex510-300

Table of Contents