Plate Brush Head; Clean Brushes; Change Brushes; Change Deflector Roller - HAKO HAKOMATIC B 90 CL Instruction Manual

Table of Contents

Advertisement

Maintenance and Care
5.7

Plate brush head

1 Toggle-type fastener
2 Brush head
3 Brush ejectors
4 Deflector roller
5 Sealing strip
Fig.10

5.7.1 Clean Brushes

Clean brushes of the brush head (Fig.
10/2) at daily intervals or as required.
Press brush ejectors (Fig. 10/3) down to
remove brushes for cleaning.
4
2
1
5

5.7.2 Change Brushes

Check brushes of the brush head for
wearing at weekly intervals. Replace
brushes if bristles are worn down to a
length of 1.5 cm.
1. Press brush ejectors (Fig. 10/3)
down to remove old brushes.
2. Push new brush under brush head
and use both hands to press it into
seating.

5.7.3 Change Deflector Roller

Check deflector roller (Fig. 10/4) at
weekly intervals or replace as required.

5.7.4 Change Sealing Strip

Check sealing strip (Fig. 10/5) at weekly
intervals or as required. Before doing
so, open toggle-type fastener (Fig. 10/
1) and remove sealing strip. Proceed to
mounting in inverse order.
3
35