START-UP AND FUNCTIONING

4.1

Preliminary checks

Remove the front panel of the boiler and per-
form the following checks before switching
the boiler on or testing any of its functions.
- Check that the fuel and water circuit shut-off
cocks are open
- Check that the type and pressure of the gas
supply are as specified for the boiler
- Check that the water circuit pressure gauge
shows a pressure over 1 bar with the system
cold. Check also that the central heating
circuit is properly de-aerated.
- Check that the pressure in the central hea-
ting circuit expansion vessel is sufficient
(about 1 bar).
- Check that the electrical connections to the
mains supply and to the system's control
and safety devices have been made cor-
rectly.
- Check that the flue is properly constructed.
4.2

Ignition

Once you have completed all the preparatory
steps, proceed as follows to start up the boiler
for the first time.
- Turn the boiler's mains power switch ON
(fig. 4.1).
Fig. 4.1
- Set the room thermostat to the required
temperature (~ 20°C) or, if the system has
a timer or timer-thermostat, make sure that
this is switched "On" and adjusted to the
required temperature (~ 20°C) (fig. 4.2).
Fig. 4.2
- Adjust the boiler's own temperature control
to the desired temperature (not necessary
if the boiler is equipped with a temperature
controller) (fig. 4.3).
Fig. 4.3
- Switch the boiler on at the control panel
switch and check that the green power indi-
cator lights (fig. 4.4).
Fig. 4.4