38 FLUE TERMINAL POSITION

The terminal should be positioned so that products of
combustion can safely disperse at all times.
Pluming may occur at the termination so, where
possible, terminal positions where this could cause
a nuisance should be avoided.
Minimum dimensions are shown below
300mm
min
Flat roof - with structure
A = 600mm
B = 2000mm
The flue terminal shall not penetrate the shaded area of the roof
32
INSTALLATION
m
0 m
3 0
i n
m
625mm
Fixed
A
A
A
B
Terminal Position
Directly below an opening,
air brick, windows, etc.
Below plastic / painted gutters
Painted surface
Below eaves or balcony
Below velux window
Above or side of velux window
3 0 0 m m
m i n
Minimum Dimension
300 mm
300 mm
300 mm
500 mm
2000 mm
600 mm