Terminal Wall Seal Assemby/Positioning; Setting The Flue - Rear; Setting The Flue - Side - IDEAL istor HE260 Installation And Servicing

Hide thumbs Also See for istor HE260:
Table of Contents

Advertisement

30 TERMINAL WALL SEAL ASSEMBLY / POSITIONING
Prior to fitting the flue, the rubber terminal wall seal provided
in the flue pack MUST be fitted to the flue terminal as shown
below in Figure 1.
isfu9783
31A SETTING THE FLUE - REAR
Notes.
a. If using the extension ducts go to Frame 34.
1. Measure and note wall thickness X. Refer to Frame 27.
2. Add 145mm (5
/
") to dimension X and set telescopic flue
1
2
length as indicated in drawing.
3. Using a 3.5mm drill bit, drill one hole in outer air duct
taking care not to pierce plastic inner flue.
4. Fix to length using self tappers provided.
5. Seal out air duct using the tape provided.
31B SETTING THE FLUE - SIDE
a. If using the extension ducts go to Frame 34.
b. For shorter flue lengths use non-telescopic B Pack.
1. Measure and note wall thickness R or L (this measurement
differs for LH and RH flues). Refer to Frame 27.
For RH flues, note that a flue extension may be needed.
For RH Side
2a. Add 300mm (11
/
") to dimension R and set telescopic flue
7
8
length as indicated in drawing.
For LH Side
2b. Add 175mm (6
/
") to dimension L and set telescopic flue
7
8
length as indicated in drawing.
3. Using a 3.5mm drill bit, drill one hole in outer air duct taking
care not to pierce plastic inner flue.
4. Fix to length using self tappers provided.
5. Seal out air duct using the tape provided.
28
INSTALLATION
FIGURE 1
Wall Seal Lip
Ensure lip of wall seal is positioned
over step on plastic nose of flue terminal
(note, seal is cut away for clarity)
Wall thicknesses of 192 to 407mm
Once the flue is installed it is IMPORTANT that the rubber
terminal wall seal is pressed against the outside wall to
create an adequate seal between the flue and wall as
shown in Figure 2.
Step
Drill hole
X + 145
ist9033
Wall thicknesses of: RHS 114 to 248mm, LHS 114 to 372mm
Drill hole
(RHS) X + 300
(LHS ) X + 175
nm8811
istor system store -
FIGURE 2
Adhere sealing tape
Measurement to be
taken from this point
Adhere sealing tape
Measurement to be
taken from this point
Installation and Servicing
Rubber
Terminal
Wall Seal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Istor he325

Table of Contents