  • Page 1 January 2010 UIN 205403 A01...
  • Page 2: Electricity Supply

    Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500 Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 3: To Light The Boiler

    To Light the Boiler. Refer to Control of water temperature F r a m e 1 Domestic Hot Water The boiler incorporates a factory fitted programmer, refer to The DHW delivery temperature is controlled by thermostatic page 5 onwards of these instructions for setting the mixer within the tank module (see illustration below).
  • Page 4: Maintenance

    To shut down the boiler Loss of system water pressure 1. For short periods The gauge (see illustration below) indicates the central heating system pressure. If the pressure is seen to fall below the Set the mains ON/OFF switch (A) to OFF original installation pressure of 1-2 bar over a period of time then a water leak is indicated.
  • Page 5: Troubleshooting

    POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.
  • Page 6 istor - User's...
  • Page 7: Battery Backup

    PROGRAMMER ISTOR ITIME PROGRAMMER USER REFERENCE GUIDE 1 2 3 TIMED TIMED ADVANCE +1hr ADVANCE PROG time prog prog select select P R O G R A M M E R INTRODUCTION The istor programmer allows the user to set the times at which they want the boiler to run for Central Heating (CH) and Domestic Hot Water (DHW).
  • Page 8 ITIME PROGRAMMER PROGRAMMING MODE STRUCTURE Once the programming mode is entered the structure is as shown: are the UP and DOWN buttons Central heating times setting / delete The left hand “Timed” is flashing, Go to Frame 3 together with the radiator symbol The Radiator symbol is flashing, Radiator temperature setting together with “...
  • Page 9: Setting The Day And Time

    ITIME PROGRAMMER SETTING THE DAY AND TIME DISPLAY SHOWS time / day is the PROG button and backlight is OFF is the SELECT button Press ‘PROG’ button briefly are the UP and DOWN buttons DISPLAY SHOWS time / day and backlight is ON Press ‘PROG’...
  • Page 10 ITIME PROGRAMMER PROGRAMMING THE HEATING (OR HOT WATER) PERIODS DISPLAY SHOWS time / day is the PROG button and backlight is OFF is the SELECT button Press ‘PROG’ button briefly are the UP and DOWN buttons DISPLAY SHOWS time / day and backlight is ON Press ‘PROG’...
  • Page 11 SETTING THE CH MAXIMUM FLOW TEMPERATURE* DISPLAY SHOWS time / day is the PROG button and backlight is OFF is the SELECT button Press ‘PROG’ button briefly are the UP and DOWN buttons DISPLAY SHOWS time / day and backlight is ON Press ‘PROG’...
  • Page 12 QUICK REVIEW OF PROGRAMMED TIMES AND TEMPERATURES Note. This section cannot be used to amend the settings, is the PROG button see Frames 3 and 4. is the SELECT button are the UP and DOWN buttons DISPLAY SHOWS time / day and backlight is OFF Press ‘PROG’...
  • Page 13: Fault Finding

    PRESET PROGRAM TIMES AND TEMPERATURES The programmer comes with preset Central Heating and Hot Water times and temperatures. These can be amended using the appropriate procedures. The times can be deleted if they are not required (refer to Frame 8). Central Heating Periods: Hot Water Periods: MON-FRI...
  • Page 14 CLEARING THE PRESET TIMES The programmer comes with preset time periods for Central Heating and Hot Water. These can be individually cleared prior to user programming using the following sequence. is the PROG button is the SELECT button DISPLAY SHOWS time / day and backlight is OFF are the UP and DOWN buttons Press ‘PROG’...
  • Page 15 istor - User's...
  • Page 16 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance Ideal Consumer Helpline of its products. The right is therefore reserved to vary specification without notice. Tel: 01482 498660 Ideal Boilers, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel.
  • Page 17 ITIME PROGRAMMER - CONTROLS AND DISPLAY "Heating" "Hot Water" Press this 1 2 3 Press this button to cycle button to cycle TIMED TIMED from 'TIMED' to from 'TIMED' to ADVANCE +1hr ADVANCE 'ADVANCE' then 'ADVANCE' then 'ON' and 'OFF'. 'ON' and 'OFF'.

This manual is also suitable for:

He 325