Supply of combustion air

When a stove is installed in a room, the demand for air supply to the
room increases. Air can be provided indirectly via a vent in the outer
wall or via a duct from the outside that is connected to the connector
on the underneath of the stove. The amount of air needed for
combustion is approx. 25m
3
/h.
The connector has an external diameter of 67 mm. When duct
routing further than 1 m the pipe diameter must be increased to 100
mm and a correspondingly larger wall vent must be selected.
In hot areas the duct should be insulated with 30 mm mineral wool
covered with a moisture inhibitor (plastic). It is important that the
lead-in between the pipe and the wall (or floor) is sealed using
jointing compound.
A 1 m length of condensation-insulated ducting for combustion air is
available as an accessory.
Installation variants
Indirect air supply through the external wall.
Through the external wall.
LEK
LEK
In the back and floor plates there are
knockouts that must be removed to insert
pipes or for air supply if the stove is
equipped with a drawer, lower hatch and/or
fan (accessory).
!
Through floor and wall-and-cavity
foundation.
Through floor and foundation slab.
SUPPLY AIR/ACCESSORY
Leave a 40 mm gap between
the condensation insulation
and the bottom of the stove.
LEK
LEK
GB
71