20

Vent Clearances

Vertical Penetrations
(through ceilings, roofs, etc.)
(firestop is required - sku 98900029)
1" Clearance To the Side
IN THE ENCLOSURE (under 78")
Vertical or Horizontal Sections:
6" Clearance Above
3-1/2" Clearance To The Side
2" Clearance Below
Vent Location
The starter section is set at a 45° angle. Place a 45° elbow directly on top of the fireplace and route it
vertically or horizontally. The approximate position of the vent is shown below.
REAR VENT
Framing to the rear of the fireplace.
NOTE: In cases where the vent is routed vertically
directly above the fireplace, you may place a 90°
elbow directly on top of the fireplace, followed by a
45° elbow that directs the vent upwards. For vent
configuration purposes this is considered a top vent
and the 90° and 45° elbow is considered a single
45° elbow.
© Travis Industries
Installation
(for qualified installers only)
1"
41-3/4"
ABOVE THE ENCLOSURE (over 78")
Vertical Sections:
1" Clearance To the Side
Horizontal Sections:
4" Clearance Above
2" Clearance To The Side
2" Clearance Below
Horizontal Penetrations
(through walls, etc.)
(thimble is required - sku 98900030)
4" Clearance Above
2" Clearance To The Side
2" Clearance Below
TOP VENT
Framing to the rear of the fireplace.
4090102
3-1/2"
46"
9-1/4"
56"
100-01212_000