FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS
SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG)
The PG36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using
two 90
elbows (two 45
elbows equal one 90
o
o
systems for LPG and NG, as per diagram 1.
The PG36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90
elbow (two 45
elbows equal one 90
o
o
GS flue systems for LPG and NG, as per the diagram 2.
•
Flue must be supported at offsets
•
Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas
Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing"
sections.
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe
(Part # 510-994).
Note: Regency
Co Axial Flue System (Flex) is only approved for horizontal terminations.
®
Regency
PG36-5 Gas Log Fireplace
®
elbow) with Simpson Dura-Vent Co Axial Flue GS flue
o
elbow) with Simpson Dura-Vent Co Axial Flue
o
Diagram 1
INSTALLATION
Diagram 2
15