OPERATING INSTRUCTIONS

ADJUSTING FLAME
HEIGHT
There are six flame settings that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FLAME button.
The FLAME setting button is located on the
control panel in behind the pedestal door.
SUMMARY OF
CONTROLS
On/Off Button
If the unit is switched off, pressing and releasing
this button once will switch the unit on. The unit
will resume its last settings.
If the unit is switched on, pressing and releasing
this button once will switch the unit off.
Flame:
Increase - If the unit is switched on, pressing
and releasing the plus (+) button once will
increase the flame height to the next available
high setting.
Decrease - If the unit is switched on, pressing
and releasing the minus (-) button once will
decrease the flame height to the next available
low setting.
Fan:
The fan speed is changed by pressing and
releasing the fan button.
It operates in 4 modes: OFF, LOW, MEDIUM
and HIGH.
32

PILOT ADJUSTMENT

Periodically check the pilot flames. The correct
flame pattern has 3 strong blue flames.
One flowing around the thermocouple, the
second flowing across the rear of the burner (it
does not have to be touching the burner) and the
third flame flowing tangent to the spark ignitor.
NOTE: If you have an incorrect flame pattern,
contact your Regency
dealer for further
®
instructions.
Rear of Burner
An incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear of the burner or
thermopile.
Rear of Burner
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are normal
operating sounds and should not be considered
as defects in your appliance.
Blower:
Regency
gas appliances use high tech blowers
®
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a different
gauge material from the rest of the firebox and
body. Therefore, the varying thicknesses of steel
will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.