MAINTENANCE
1) Shut off the gas supply.
2) Remove the louvres.
3) Open the flush door and remove door.
4) Remove the logs.
5) Remove the burner/grate assembly by removing the left and right
side Philips head screws and then lift the burner assembly out.
Left Side Shown
Lift out the burner/grate assembly.
6) Remove the rear log log stand by removing the 2 screws.
Rear Log Stand
7) Disconnect the inlet gas line.
8) Remove the 10 Philips screws which secure the valve tray
assembly.
36
REMOVING VALVE TRAY
Right Side Shown
9) Remove the front cover by removing the 2 screws which secure the
front cover to the valve tray.
Front Cover
10) Unplug the 2 orange wires from the Gas Pressure Electric
Modulator.
11) Unplug the 5 pin Molex Connector from the valve.
12) Unplug the ignitor and flame cables from the module and then lift the
entire valve tray assembly out.
Flame Cable
5 Pin Molex
2 Orange
Connector
Wires
13) To replace the burner tray assembly reverse these instructions.
14) Check for any gas leaks.
15) Check for proper flame appearance and glow on logs.
Ignitor Cable
Module
Valve Tray
Assembly
Regency
PG36-5 Gas Log Fireplace
®