Zero Clearance Room
Sealed Gas Fireplace
See Thru
PG121-NG
Left Corner
PG121LC-NG
Right Corner PG121RC-NG
Pier
PG131-NG
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
PG121-LPG
PG121LC-LPG
PG121RC-LPG
PG131-LPG

Advertisement

Table of Contents
loading

Summary of Contents for Regency PG121-NG

  • Page 1 Owners & Installation Zero Clearance Room Sealed Gas Fireplace See Thru PG121-NG PG121-LPG Left Corner PG121LC-NG PG121LC-LPG Right Corner PG121RC-NG PG121RC-LPG Pier PG131-NG PG131-LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Your unit should be serviced annually by an authorised service...
  • Page 2 Association for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace. IMPORTANT: If the unit is to be installed into a bathroom, optional Neo ceramic glass Part# 360-946 Front or Part# 360-948 Side must be purchased and installed in place of the tempered glass supplied with the unit.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Label ............... 4 Operating Instructions ..........29 Lighting Procedure ............ 29 Shutdown Procedure ..........29 First Fire ..............29 Important Message ............ 5 Normal Operating Sounds of Before You Start ............5 Gas Appliances ..........29 General Safety Information .........
  • Page 4: Safety Label

    SAFETY LABEL NOTE:...
  • Page 5: Before You Start

    INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION INSTALLATION CHECKLIST Note: These units are non-load bearing. BEFORE YOU START CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsi- bility of the manufacturer.
  • Page 6: Specifications

    INSTALLATION SPECIFICATIONS Note: These units are non-load bearing.
  • Page 7 INSTALLATION Note: These units are non-load bearing.
  • Page 8: Locating Your Fireplace

    INSTALLATION LOCATING YOUR GAS FIREPLACE A) PG121 - See Thru B) PG131 - Pier C) PG121LC - Left Corner Note: For Exterior Flue Termination Locations see page 12. D) PG121RC - Right Corner...
  • Page 9: Clearances

    INSTALLATION CLEARANCES Clearance to Combustibles from: Back Side Floor CAUTION REQUIREMENTS: The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoffs may NOT be recessed into combus- tible construction. Determine the total thickness of the finished floor (eg. tile, carpet, slate) to allow the finished surface to be flush with the base of the unit.
  • Page 10: Framing And Finishing

    INSTALLATION FRAMING AND FINISHING PG121 (See Thru) PG131 (Pier) PG121LC / PG121RC (Corner Unit) CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc.
  • Page 11: Facing And Finishing Requirements

    INSTALLATION FACING & FINISHING REQUIREMENTS FLUEING UNIT ASSEMBLY INTRODUCTION PRIOR TO INSTALLATION Note: These flue pipes must not be con- nected to any other appliance.
  • Page 12: Exterior Flue Termination Locations

    INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS...
  • Page 13 FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the PG121/PG121LC/ PG121RC/PG131 with a maximum run of 2 feet. 5) AstroCap Notes: 1) Liner sections should be continuous without any joints or seams.
  • Page 14: Flueing: Direct Vent System (Flex)

    The Regency AstroCap is certified for installations using FPI venting systems as well as Simpson Dura-Vent® and Direct Vent GS. Regency , and Regency AstroCap are the proprietary trade- marks of FPI Fireplace Products International Ltd. Simpson Dura-Vent Dura-Vent® and Direct Vent GS are registered and/or propri- etary trademarks of Simpson Dura-Vent Co.
  • Page 15: Flueing Arrangements Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) Note: 1) A maximum of three 90 elbows are permitted. Simpson Dura-Vent 2) Minimum distance between elbows is 1 ft. (305mm). 4" inner diameter 6-5/8" outer diameter •...
  • Page 16 INSTALLATION 2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max. 1' (305mm) Minimum 2' (610mm) Maximum 3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max. 2' (610mm) Minimum 5' (1.5m) Maximum 4' (1.22mm) Min. 5' (1.5m) Max. 9' (2.7m) Max. 3' (914mm) Minimum 8' (2.4m) Maximum 5' (1.5m) Min.
  • Page 17 INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) • Flue must be supported at offsets • Maintain clearances to combustibles as listed on page 9. • Firestops are required at each floor level and whenever passing through a wall. •...
  • Page 18 INSTALLATION 1' (305mm) Minimum 2' (610mm) Maximum 1' (305mm) Minimum 4' (1.22m) Maximum 2' (610mm) Minimum 4' (1.22m) Maximum 2' (610mm) Minimum 6' (1.86m) Maximum 3' (914mm) Minimum 6' (1.86m) Maximum 3' (914mm) Minimum 9' (2.7m) Maximum 4' (1.22m) Minimum 8' (2.4m) Maximum 4' (1.22m) Minimum 12' (3.6m) Maximum...
  • Page 19 INSTALLATION 2' (610mm) Minimum 3' (914mm) Maximum 3' (914mm) Minimum 6' (1.86m) Maximum 4' (1.22m) Minimum 9' (2.7m) Maximum 5' (1.5m) Minimum 12' (3.6m) Maximum Please note minimum 1 foot between 90 elbows is required. Diagram 12 HORIZONTAL INSTALLATIONS Install the flue system according to the manufacturer's instructions included with the components.
  • Page 20: Vertical Terminations

    INSTALLATION VERTICAL TERMINATION Diagram 3 to ensure that the termination is not recessed into the siding. Diagram 1 Diagram 4: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments.
  • Page 21: Installation Procedures

    INSTALLATION The liners must slip over the collars a minimum of 1-3/8". Note: To make the installation more aesthetically pleas- ing, recom- mend framing out a square to mount the terminal to. be used to ensure that the termi- nation is not recessed into the siding.
  • Page 22 INSTALLATION Conversion Kit for NG to LPG Model #736-969 Front Cover brick panel is very fragile - handle with care. Pilot Pilot Pilot Pilot Tube Extrusion Orifice Assembly Tube 5 Pin Molex Connector Diagram 1: Remove the left and right screws and then slide the burner assembly away from the orifice and lift out.
  • Page 23 INSTALLATION Minimum pressure: NOTE: Cable Jumper Location Electric Modulator Jumper WARNING: Adjusting the Outlet Pressure Maximum pressure: NOTE:...
  • Page 24: System (Flex)

    Burner Inlet Orifice Sizes: Note: If you have an incorrect flame pat- Pilot Orifice LPG tern, contact your Regency dealer for further instructions. Max. Input Rating Min. Input Rating Incorrect flame pattern will have small,...
  • Page 25: Log Installation

    INSTALLATION LOG INSTALLATION do not force into position. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. Please note that there are 2 of each log. This log set is mirrored front and back.
  • Page 26 INSTALLATION Caution: Do NOT cover burner ports. Grate Post Place Log 329 onto pin. Grate Post...
  • Page 27: Glass Door Removal

    INSTALLATION GLASS DOOR FINISHING TRIM LOUVERS & GRILLS REMOVAL NOTE: Do not tighten the screw entirely, ensure that some room is left to be able to hang the grill or louver over the screw. Slide Trim into slot. Push trim tight against magnet.
  • Page 28: Remote Control (Optional)

    INSTALLATION REMOTE CONTROL WIRING DIAGRAM ORANGE BLUE PILOT MODULATING ORANGE GREEN (MD) FLAME SENSOR COIL SPARK IGNITOR BROWN SIGMA 845 VALVE MODULE - SPARK MODULE - FLAME SIT 201 IGNITION CONTROL MODULE MODULE - GROUND 12 11 8 7 6 5 4 3 2 GREEN BLACK JUMPER...
  • Page 29: Operating Instructions

    OPERATING INSTRUCTIONS OPERATING RESETTING FAN OPERATION INSTRUCTIONS THE UNIT SHUTDOWN INSTRUCTIONS ADJUSTING FLAME LIGHTING HEIGHT INSTRUCTIONS...
  • Page 30: First Fire

    OPERATING INSTRUCTIONS AERATION FIRST FIRE NORMAL OPERATING ADJUSTMENT SOUNDS OF GAS APPLIANCES 10mm open 10mm open normal operating sounds NOTE: This adjustment is only to be made by an authorised person. Blower: Note: When the glass is cold and the appliance is lit, it may cause con- densation and fog the glass.
  • Page 31: Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS MAINTENANCE INSTRUCTIONS A ) BEFORE LIGHTING smell all around the appliance B) Do not use this appliance if any part has been area for gas. Be sure to smell next to the floor under water.
  • Page 32: Log Replacement

    MAINTENANCE DOOR GLASS VALVE TRAY REMOVAL LOG REPLACEMENT Note: Improper positioning of logs may create carbon build-up and will The brick panels are very fragile severely alter the unit's perform- - handle with care. ance which is not covered under warranty.
  • Page 33 MAINTENANCE 5 Pin Molex Connector Remove Left & Right Side Base Brick Panels Igniter and 5 Pin Molex Flame Cables Connector from the Valve. Remove the 2 Long Base Brick Panels...
  • Page 34: Electronic Components List

    PARTS LIST ELECTRONIC COMPONENTS PARTS LIST 910-915 910-082 910-089 910-088 910-912 910-084 910-526 910-080 910-906 910-083 910-514 910-521, 910-522, 910-523 910-916 Fan Resistor Intermittent Pilot Direct Spark Ignitor Flame Cable Spark Cable Control Box Manual Control Valve Control Box Cable N/A* Control Box Cable Control Box Cable...
  • Page 35 PARTS LIST PG121 (SEE THRU) MAIN ASSEMBLY Part # Description Part # Description Part # Description...
  • Page 36 PARTS LIST PG131 (PIER) MAIN ASSEMBLY Part # Description Part # Description Part # Description...
  • Page 37 PARTS LIST PG121RC (RIGHT CORNER) MAIN ASSEMBLY Part # Description Part # Description Part # Description...
  • Page 38 PARTS LIST PG121LC (LEFT CORNER) MAIN ASSEMBLY Part # Description Part # Description Part # Description...
  • Page 39 PARTS LIST PG121/PG121LC/PG121RC/PG131 BURNER ASSEMBLY & LOG SET Part # Description...
  • Page 40 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 41 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 42 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 43: Warranty

    Electrical components such as fans, switches, wiring, product. thermodiscs, remote control, thermopiles, thermocouples Regency Industries Ltd., shall in no event be liable for any and gas valves are covered for one year from the date of special, indirect consequential damages of any nature purchase.

Table of Contents