LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4553, NZS 5262
and have been certified by the Australian
Gas Association for installation and op-
eration as described in these Installation
and Operating Instructions.
Your unit should be serviced annu-
ally by an authorised service person.
Zero Clearance Room
Sealed Gas Fireplace
STYLE
See Thru
PG121-NG1
Left Corner
PG121LC-NG1
Right Corner PG121RC-NG1
Pier
PG131-NG1
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
918-648d
MODEL
PG121-LPG1
PG121LC-LPG1
PG121RC-LPG1
PG131-LPG1
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
08/04/15

Advertisement

Table of Contents
loading

Summary of Contents for Regency PG121-NG1

  • Page 1 Owners & Installation Zero Clearance Room Sealed Gas Fireplace STYLE MODEL See Thru PG121-NG1 PG121-LPG1 Left Corner PG121LC-NG1 PG121LC-LPG1 Right Corner PG121RC-NG1 PG121RC-LPG1 Pier PG131-NG1 PG131-LPG1 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera-...
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 has been approved by the Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    Glass Door Removal ..........27 Finishing Trim ............27 Louvers and Grills............. 27 Remote Control (optional) ........28 Remote Wall Switch (optional) ......... 28 Wall Thermostat (optional)........28 Wiring Diagram ............28 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 4: Data Badge

    We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 5: Installation

    (wood, paper, cardboard, coal, etc.) causes sooting or carboning that results be used in this appliance. in damage is not the responsibility of the manufacturer. 14) The appliance area must be kept clear and Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 6: Specifications

    INSTALLATION SPECIFICATIONS PG121-1 - See Thru Note: These units are non-load bearing. PG131-1 - Pier Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 7 INSTALLATION PG121LC-1 - Left Corner Unit Note: These units are non-load bearing. PG121RC-1 - Right Corner Unit Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 8: Locating Your Gas Fireplace

    Have a authorized inspector, dealer, or installer review your plans before installation. C) PG121LC-1 - Left Corner Note: For Exterior Flue Termination Locations see"Exterior Flue Termina- tion" section. D) PG121RC-1 - Right Corner Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 9: Clearances

    Caution: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. * If the 3" (76mm) metal extension trim is removed it must be replaced with a 8" (203mm) non-combustible material. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 10: Framing And Finishing

    You must maintain clearance from the flue to combustible materials for both rigid and flex. PG121LC-1 - Corner Unit PG121-1 - See Thru PG131-1 - Pier PG121RC-1 - Corner Unit Note: These units are non-load bearing. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 11: Facing And Finishing Requirements

    Each direct flue gas appliance must use it's own separate flue system. Common flue systems 3) Attach the standoff securely to the top with are prohibited. 4 screws per standoff (on opposite corners). Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 12: Exterior Flue Termination Locations

    (IV) A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 13: Flueing: Direct Vent System (Flex)

    Warnock Hersey. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram. Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 with a maximum run of 2 feet.
  • Page 14: Flueing: Simpson Dura-Vent Direct Vent Gs

    FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. SIMPSON DURA-VENT FLUEING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency. Part # Description Part # Description Part # Description 940 Wall Thimble - Support/Box Horiz.
  • Page 15: Flueing Arrangements Horizontal Terminations

    With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 1 Diagram 2 Please note the minimum centerline for basic install shown above. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 16 12' (3.6m) Max. With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 4 Diagram 6 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 17: Vertical Terminations

    8' (2.4m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 7 Diagram 8 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 18 8' (2.4m) Max. 12' (3.6m) Max. With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 11 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 19: Flueing - Dura-Vent Horizontal Installations

    Diagram 1. Push the pipe sections of run towards the termination. Never 7) Before connecting the horizontal run of flue completely together, then twist-lock allow the flue to run downward. This Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 20: Flueing - Dura-Vent Vertical Termination

    11/12 to 12/12 1.22 over 12/12 to 14/12 1.52 over 14/12 to 16/12 1.83 over 16/12 to 18/12 2.13 over 18/12 to 20/12 2.29 Diagram 5 over 20/12 to 21/12 2.44 Diagram 3 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 21: System (Flex)

    Note: If installing termination on a siding covered wall, furring strips must be used to ensure that the termination is not recessed into the siding. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 22: Conversion From Ng To Lpg

    15) Carefully pull out the control box from un- and lift out. allen key. derneath the fi rebox. Note: The control box is held in place with velcro. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace 12/20/06 918-578...
  • Page 23 LPG" on the control box the plastic cap (A) is returned to its original cover. location. 19) Reverse steps 16 and 15. 20) Turn on gas supply and plug in power cord. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 24: System Data

    Note: To properly check gas pressure, both that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement. Important: Always check for gas leaks with Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 25: Log Set Installation

    When placing Embers, do not block burner ports as this can cause an incorrect fl ame pattern, Tab on Burner Grate Post carbon deposits and delayed ignition. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace 01/03/08 918-111c Page 1 of 2...
  • Page 26 Repeat step 6 on the opposite side of the burner. on Log 326. Grate Post Completed Log Set Installation: Repeat step 5 on the opposite side of the burner. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace 01/03/08 918-111c Page 2 of 2...
  • Page 27: Glass Door Removal

    Corner Model: Remove the 6 screws that Push trim tight The Top and Bottom Side Louver or Grill is secure the glass door and repeat step 2. against magnet. installed the same way. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 28: Remote Control (Optional)

    INSTALLATION REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter and a wall mounting plate. 1) Choose a convenient location to mount the hand held transmitter, protection from extreme heat is very important.
  • Page 29: Operating Instructions

    The FLAME setting button is located on the ignition system will spark for 40 seconds to control panel in behind the pedestal door. light the main burner. 4) If the main burner does not light, reset the unit. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 30: Operating Instructions

    Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 31: Lighting Plate Instructions

    These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents should be replaced immediately. 2) Remove the Cap, and shine a flashlight down the Flue. Remove any bird nests, or other foreign material. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 32: Log Replacement

    DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Clean any fingerprints off before turning the unit on. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 33 14) Unplug the igniter and the flame cables from the module. Remove Left & Right Side Base Brick Panels Igniter and Flame 5 Pin Molex Con- nector from the Cables Valve. Remove the 2 Long Base Brick Panels Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 34: Manual Control Replacement

    11) Put the ECS box back in place under the firebox. 12) Reverse steps 5 to 1. Valve Heat Shield 6) Pull out the ECS box by carefully lifting it up off the velcro. ECS Box Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 35: Parts List

    910-527 Manual Control Switch    910-935 Manual Control Switch      *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 36: Replacement/Spare Parts List

    Brick Panel - Base - Front 360-924 Louver Front - Black/Steel (set) 33) 362-528 Brick Panel - Base - Side 360-926 Louver Front - Black/Brass (set) 34) 902-603 Brick Panel - Side Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 37 Louver Side - Black/Brass (set) 32) 362-528 Brick Panel - Base - Side 33) 362-528 Brick Panel - Base - Front 34) 902-603 Brick Panel - Side 141) 360-031 Column Finishing Trim Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 38 360-936 Louver Side - Black/Steel (set) 33) 362-528 Brick Panel - Base - Front 360-938 Louver Side - Black/Brass (set) 34) 902-603 Brick Panel - Side 35) 902-604 Brick Panel - Front Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 39 Brick Panel - Base - Front 360-934 Louver Side - Black/Gold (set) 34) 902-603 Brick Panel - Side 360-936 Louver Side - Black/Steel (set) 35) 902-604 Brick Panel - Front 360-938 Louver Side - Black/Brass (set) Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 40 Pilot Assembly - LPG 67) * Pilot Holder 68) W840470 Pilot Assembly Gasket 79) 360-525 Burner Assembly 82) 360-027 Grate Assembly 904-690 Orifice #31 - NG 936-170 Orifice Gasket *Not available as a replacement part. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 41 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 42: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 43 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 44 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

Table of Contents