Begin Installation - Fleck 7000 SXT Installation Manual

Hide thumbs Also See for 7000 SXT:

Advertisement

Begin Installation

 Attaching the Bypass
valve
Copyright © 2012 Quality Water Treatment, All right reserved. rev. 4.19.2013
1. Turn off the main water shut off valve.
2. Open all plumbing fixtures in the house including the outside faucets in order to drain the lines.
Unscrewing the aerator screen from your bathroom and kitchen faucets will help drain the lines faster.
3. Cut and remove a 4" section of the water line where the unit is to be installed.
4. Remove the plastic clips that are connected between the plastic bypass and the plastic meter assembly.
Remove the bypass valve from the meter assembly by pulling it away from the meter assembly. Notes: Be
sure to leave the meter assembly in place. If soldering we do not recommend applying heat from a
soldering torch to solder copper pipe to new valve/meter assembly.
5. Solder adapters of your choice to copper tales we provided or glue adapters to pvc tales if you ordered
your system with that option.
6. Once the pieces of 1" or 1 1/4" Adapters of your choice are soldered or glued into the adapters wait until
they are cool enough to touch.
7. Re-attach the plastic bypass valve back onto the valve/meter assembly and secure it with red clips
Page 3 of 17
Please follow the instructions below step by step in order to correctly
complete the installation of your new water softener from Quality Water
Treatment.