As all above Led display and error code, they will be checked in the Error Mode
when system gets error or problem.
When there are two conditions as below appearing, you must enter Error Mode.
1. Lamp Extinguish
2. After system light "Red" Led, then it will enter Error Mode once system get error message again.
(Ex: When Lamp A light "Red" Led, it will switch to Lamp B. Once Lamp B gets any error message,
system will enter Error Mode.)
The projector would echo the following messages as follow for"op prerr ":
op prerr
OPPRERRErrMsg:
1 SYS: 0015 .
2 SYS: 0017
3 >>> BErr= 0063
4 sys: 0032Run*LS
5 >>> BErr = 0063
6 sys: 0032Init*LS
7 >>> BErr= 0000
Illustrate above messages as follow:
1 SYS: 0015.............. ( the projector is shut down because of error code 15)
2 SYS: 0017 ...............( the projector is shut down because first lamp lite fail, lamp lite Error as below "3 >>>BErr =
XXXX" )
3 >>> BErr= XXXX .............( XXXX is the ballast error code.. usually cause the lamp fail <above SYS: 0017 > )
4 sys: 0032Run*LS .....( the lamp is swap when projector is running because lamp lite fail,
single lamp mode
with led flash 1 times per second )
6 sys: 0032Init*LS ........( the lamp is swap to one lamp mode on projector initial lamp process ,
on single lamp mode
with led flash 1 times per second )
Please refer to
Error Code Description list
for other error issue
- 24 -
projector is still working on
projector is still working