6

System examples

6
System examples
6.1

Information regarding all system examples

The system examples in this chapter provide information
regarding the standard systems that are feasible with the
Logamatic EMS control system.
The practical implementation is subject to currently
applicable technical rules. Install safety equipment in
accordance with local regulations.
The circuit diagrams are only schematic illustrations and
provide a non-binding indication of possible hydraulic
circuits.
List of abbreviations
Abbr.
Explanation
AW
DHW outlet
BC10
Base controller
EK
Cold water inlet
EZ
DHW circulation inlet
Outside temperature sensor (standard delivery of the
FA
RC35 programming unit for weather-compensated
control)
FAG
Flue gas temperature sensor
FB/FW
DHW temperature sensor
FEK
Cold water temperature sensor
FK
Flow temperature sensor
FP
Buffer cylinder temperature sensor
FPO
Buffer cylinder top temperature sensor
FPU
Buffer cylinder bottom temperature sensor
FR
Return temperature sensor
FS
Safety temperature sensor
FSK
Collector temperature sensor
FSS
Cylinder temperature sensor
FV
Flow temperature sensor
FW/FB
DHW temperature sensor
GAS
Gas connection
G-KS
"Short circuit" line
HK
Heating circuit
HKV
Heating circuit distributor
HS...
Heating circuit quick installation set
FE
Drain & fill valve
KR
Check valve
MAG
Diaphragm expansion vessel
MM10
Mixer module
PH
Heating circuit pump (secondary pump)
PK
Boiler circulation pump
PP
Heat source pump
PS
Cylinder primary pump
PSS
Solar circuit pump
PZ
DHW circulation pump
RC..
Programming unit
RDD
Differential pressure controller
RH
Heating system return
RK
Boiler return
RS
DHW cylinder return
Table 21 Overview of frequently used abbreviations
52
Abbr.
Explanation
SA
Branch control and shut-off valve
SH
Heating circuit actuator (3-way mixer)
SM10
Solar module
SMF
Dirt filter
SPB
Actuator, heat supply
SU
3-way diverter valve
SV
Safety valve
THV
Thermostatic valve
TW
Domestic hot water
TWH
Temperature limiter - underfloor heating circuit
ÜS
Surge protector
ÜV
Overflow valve
VH
Heating circuit flow
VK
Boiler flow
VS
DHW cylinder flow
WH
Low loss header
WM10
Low loss header module
WS
Water flow sensor
WT
Heat exchanger for system separation
WWM
Thermostatic DHW mixer
ZV
Zone valve
Table 21 Overview of frequently used abbreviations
6 720 645 821 (2010/09) – Logamax plus GB162