Buderus Logamax plus GB162 Technical Manual page 102

Gas condensing boiler output range from 2.7 kw to 100 kw
Hide thumbs Also See for Logamax plus GB162:
Table of Contents

Advertisement

8
Installation
Accessories
Connection set ES0
Adaptor set ÜS1
Adaptor set ÜS2
Adaptor set ÜS3
Adaptor set
Pipe assembly
for heat meter
Pipe assembly
for system separation
Table 38 Accessories
1) Max. GB162-80
All EC pumps can be manually switched to
operate in their various stages.
At ΔT = 20 K the following can be used:
HSM 15 E plus
K
HSM 20 E plus
K
HSM 25 E plus
K
HSM 32 E plus
K
102
Product no.
Logamax plus
67 900 475
ES0 for heating circuit connection set DN15/20/25 fitted on distributor DN32
63 012 350
For connecting a heating circuit quick installation set DN32 to a distributor DN25
For HKV 32 combined with HS 25, HSM 15/20/25
63 210 008
Installed height 50 mm
For the same installed height of DN15/20/25 with DN32
63 034 128
Adaptor set G1½ to G1¼
5 024 886
DN40 to DN32, with flat gaskets, G2 to G½
DN40 to DN32, conical, G2 to R1½
5 024 888
For connecting distributors HKV 4/25/40 and HKV 5/25/40
For installation upstream of the heating circuit set, installed height approx. 200 mm
For standard heat meters made by Pollux and Deltamess
Installed length, heat meter
80 680 154
– 110 mm, ¾ "
80 680 156
– 130 mm, 1"
For existing systems with pipes permeable to oxygen; black thermal insulation
For system separation, installed height approx. 200 mm, DN25
Max. 15 kW with Grundfos Alpha 2, ΔT = 10 K
For installation below a heating circuit quick installation set DN15/DN20/DN25
80 680 158
With safety valve 3 bar
With pressure gauge, fill & drain valve and air vent valve; stainless steel plate heat
exchanger
Minimum clearance of 150 mm required on the r.h. side
3
= 2.5 m
/h to 16 kW
VS
3
= 6.3 m
/h to 40 kW
VS
3
= 8.0 m
/h to 45 kW
VS
3
= 18.0 m
/h to 55 kW
VS
6 720 645 821 (2010/09) – Logamax plus GB162