Buderus Logamax plus GB162 Technical Manual page 121

Gas condensing boiler output range from 2.7 kw to 100 kw
Hide thumbs Also See for Logamax plus GB162:
Table of Contents

Advertisement

Fig. 108 Components of the standard GA-X set in plastic, in conjunction with the standard GA-K set (
page 148) or LAS-K (
A
Flue gas
B
Ventilation air
Concentric air/flue gas routing in open flue operation with GA-X set
Standard GA-X set for Logamax plus GB162 up to 35 kW
GA-X in PP plastic/zinc-plated steel (painted white), Ø 80/125 mm
For concentric air/flue gas routing via a flue with secondary ventilation in a shaft, the standard GA-X set is
only permissible in conjunction with the standard GA-K set (GA-K in conjunction with GA-X only
permissible up to 35 kW).
For combining the standard GA-Xset with standard GA-K set:
GA-K in PP plastic/zinc-plated steel (painted white), Ø 80/125 mmWith shaft cover and terminal pipe
1)
made from stainless steel
Air grille
For concentric air/flue gas routing via a moisture-resistant flue system (multiple connection), the standard
GA-X set is only permissible in conjunction with the LAS-K set (LAS-K in conjunction with GA-X only
permissible up to 35 kW).
For combining the standard GA-X set with the standard LAS-K set:
LAS-K in PP plastic/zinc-plated steel (painted white), Ø 80/125 mm
Optional equipment
Components for the air/flue gas line inside the installation room and for flues in shafts with
secondary ventilation:
The additional equipment to supplement the standard GA-K set is listed for the Logamax plus GB162 up
to 45 kW. However, the use of the GA-K set in conjunction with GA-X is only permissible, in accordance
with the DVGW-TRGI 2008 [Germany], up to a total rated output of the open flue combustion equipment
of up to 35 kW.
Components for the air/flue gas line inside the installation room:
The additional equipment to supplement the standard LAS-K set is listed for the Logamax plus GB162 up
to 45 kW. However, the use of the LAS-K set in conjunction with GA-X is only permissible, in accordance
with the DVGW-TRGI 2008 [Germany], up to a total rated output of the open flue combustion equipment
of up to 35 kW.
Table 50 Components of the GA-X set in conjunction with the GA-K set or LAS-K
1) Not in connection with ÜB-Flex
6 720 645 821 (2010/09) – Logamax plus GB162
GA-K
GA-X
1
B
B
LAS-K
tab. 81, page 158)
Flue systems for open flue operation
)
1
)
1
1
Concentric pipe with ventilation air grille, gasket for the
ventilation air pipe at the female connection
1)
Alternative
A
6 720 641 280-52.1il
table 71,
Product no.
Details
87 094 528
fig. 108
77 472 153 65
fig. 141, page 149
77 472 153 66
87 092 146
fig. 107
77 472 153 70
fig. 154, page 159
Table 72, page 149
Table 82, page 159
9
121